Abstract:
Background: Atypical atrial flutter (AFL) can be challenging to ablate, especially when involving dual-loop re-entry. We sought to assess the electroanatomical characteristics of single- and dual-loop AFLs in patients undergoing catheter ablation. Methods: We analyzed 25 non-cavotricuspid isthmus-dependent macro-re-entrant AFL in 19 consecutive patients. Three-dimensional high-density activation mapping was performed, and active re-entry loops were confirmed by entrainment mapping. Results: Of 25 AFLs (24 left, 1 right atrial), 13 (52%) exhibited dual-loop re-entry. The most common circuits included, in 6/13 (46% of dual loops), a perimitral re-entry with a second loop around the right/left pulmonary veins (PV) and, in 6/13 (46%), involved a right PV ostium with a second loop around either a functional conduction block or another PV. Ablation at the common isthmus of dual-loop AFLs and at the critical isthmus of single-loop AFLs terminated the arrhythmia more frequently than ablation at a secondary isthmus of dual-loop AFLs (5/6 (83%) and 8/11 (73%) versus 1/8 (13%), respectively, p = 0.013). Conclusions: More than half of AFLs exhibited a dual-loop re-entrant mechanism. Most critical isthmuses were found at the mitral isthmus, the left atrial roof or right PV ostia. Ablation targeting the common isthmus resulted in a higher termination rate.
More Related Videos
09:13Remote Magnetic Navigation for Accurate, Real-time Catheter Positioning and Ablation in Cardiac Electrophysiology Procedures
Published on: April 21, 2013
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019
Related Concept Videos
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow...
Mechanism of Cardiac Arrhythmias
Cardiac Action Potential
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials