Miscibility of amorphous solid dispersions: A rheological and solid-state NMR spectroscopy study
Sichen Song1, Jianchao Xu2, Zhenxuan Chen3
1Department of Pharmaceutics, University of Minnesota, Minneapolis, MN 55455, United States; School of Mathematics, University of Minnesota, Minneapolis, MN 55455, United States.
Abstract:
Miscibility is critical in the prediction of stability against crystallization of amorphous solid dispersions (ASDs) in the solid state. However, currently available approaches for its determination are limited by both theoretical and practical considerations. Recently, a rheological approach guided by the polymer overlap concentration (c*) has been proposed for miscibility quantification of ASDs [J. Pharm. Sci., 112 (2023) 204-212] and shown to be useful in predicting both accelerated and long term physical stability in the absence of moisture. However, this approach can only be performed at high temperatures (slightly above the melting temperature, Tm, of drugs), and little is known about the difference in miscibility between high and low temperatures (e.g., below the glass transition temperature, Tg). Here we compare the miscibility of nifedipine (NIF)/polyvinylpyrrolidone (PVP) ASDs as determined by the rheological approach at 175°C (∼3°C above Tm of NIF) and solid state NMR (ssNMR) 1H T1 and T1ρ relaxation times at -20°C (∼66°C below Tg of NIF). Our results indicate agreement between the two methods. For low molecular weight (Mw) PVP, T1ρ measurements are more consistent with the rheological approach, while T1 measurements are closer for relatively high Mw PVP. Our findings support the use of the c* based rheological approach for inferring miscibility of deeply cooled ASDs.
More Related Videos
11:38Combining Microfluidics and Microrheology to Determine Rheological Properties of Soft Matter during Repeated Phase Transitions
Published on: April 19, 2018
07:51Dielectric RheoSANS — Simultaneous Interrogation of Impedance, Rheology and Small Angle Neutron Scattering of Complex Fluids
Published on: April 10, 2017
Related Concept Videos
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are...
Polymer Classification: Crystallinity
Crystalline domains are the regions where polymer chains are aligned in an orderly manner and held together in proximity by intermolecular forces. For example, chains in the crystalline domains of polyethylene and nylon are bound together by van der Waals...
¹H NMR of Conformationally Flexible Molecules: Temporal Resolution
NMR Spectroscopy Of Amines
¹H NMR of Conformationally Flexible Molecules: Variable-Temperature NMR
Solution Formation
This selective...