Related Experiment Video
Updated: Jun 24, 2025

Evaluation of Capnography Sampling Line Compatibility and Accuracy when Used with a Portable Capnography Monitor
Published on: September 29, 2020
Single centre observational study evaluating the impact of introducing High Flow Nasal Cannula outside of Paediatric
Shil Patel1, John Hunter1, Patrick Davies1
1Nottingham University Hospitals, Nottingham, United Kingdom.
Aim:
To evaluate the impact of High Flow Nasal Cannula (HFNC) introduction outside of Paediatric Critical Care Units (PCCU), on PCCU admissions and intubation rates. Secondarily, to identify escalation predictors.
Methods:
Retrospective observational study with matched PCCU admissions and intubation rates, 2-years before (Group 1) and 2-years after (Group 2) HFNC introduction outside of PCCU. Within Group 2, we compared those admitted to PCCU (escalation) and those who did not (non-escalation). Observations, change in observations and time to starting HFNC were analysed.
Results:
Pre- and post-introduction comparison: Of 980 admissions in Group 1, 55 were admitted to PCCU, whereas of 1209 admission in Group 2, there were 85 admissions, P = 0.188. Group 1 had 25 intubations compared to 23 in Group 2, P = 0.309. Over twice as many children had some form of respiratory support in Group 2. Post-introduction: 104 children commenced HFNC, 72% for bronchiolitis. Median age was 4 months in the non-escalation group and 6.5 months in the escalation group, P = 0.663. Thirty-eight children escalated to PCCU: 33 required CPAP/BiPAP, 4 were intubated with 1 remaining on HFNC. Comparisons of age, gender, comorbidities, observations, change in observations and time to starting HFNC showed no significant escalation predictors.
Conclusions:
This study identified no statistically significant predictors of escalation. There was an observed increase in PCCU admissions with decreased intubations. The resource implications of this therapy are significant and further studies should examine cost effectiveness of HFNC use outside of PCCU.
More Related Videos
Related Concept Videos
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Suctioning the Nasopharyngeal Airway
Equipment Required
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...