Related Experiment Video
Updated: Jun 24, 2025

Measurements of Local Instantaneous Convective Heat Transfer in a Pipe - Single and Two-phase Flow
Published on: April 30, 2018
Method to determine instantaneous transient responses in pressurized pipes from transfer functions and state space
Edgar Orlando Ladino-Moreno1, César Augusto García-Ubaque1, Oscar Gabriel Espejo-Mojica1
1Universidad Distrital Francisco José de Caldas, Bogotá, Colombia.
Abstract:
This article addresses the impact of transient pressure anomalies in hydraulic systems, triggered by the opening or closing of valves or pumps, instantly disturbing the line of hydraulic gradient (LGH). This variation in pressure has significant consequences both in hydraulic and structural terms for water networks. Most of the existing techniques to detect transients in water distribution systems use asynchronous methods, generating timeless information that limits the response capacity in critical situations. Therefore, an automatic transient detection system based on the Internet of Things (IoT) is proposed, capable of identifying overpressure or underpressure pulses in soft real-time, activating alarms to facilitate decision-making. This approach helps maintain the safety of the water distribution system and prevent leaks in the network. Furthermore, a model of the transient behavior of pressure and flow is presented by linearizing the water hammer equations from the Laplace transform, thus generating a transfer function that describes the algebraic relationship between the outlet and inlet of the hydraulic system.•The transient analysis of the hydraulic system prototype underscores its high sensitivity to initial conditions, attributed to turbulence. This observation suggests the possible presence of a dynamic strange attractor related to water hammer phenomena in pressure pipes.•The methodology involving transfer functions and state-space models enables the assessment of how leaks impact the transient responses of the system, including the magnitude, duration, and frequency of disturbances generated by them.•The proposed method introduces a dynamic transfer function capable of identifying instantaneous changes over time in terms of flow and pressure.
Related Concept Videos
Single Pipe Systems
In a Type I problem, fluid properties (density and viscosity), pipe characteristics (including diameter, length, and surface roughness), and the flow rate or average velocity are...
Transient and Steady-state Response
These test signals are integral in designing control systems to exhibit two key performance aspects: transient response and steady-state...
Pipe Flowrate Measurement: Problem Solving
Design Example: Designing a Residential Plumbing System
Major Losses in Pipes
Fluid flow can be classified as laminar or turbulent, primarily based on the Reynolds number. This dimensionless number reflects the relative influence of inertial to...
General Characteristics of Pipe Flow I
The classification of fluid...