In-situ Audiometry Compared to Conventional Audiometry for Hearing Aid Fitting.
Maaike Van Eeckhoutte1,2, Bettina Skjold Jasper1,2, Erik Finn Kjærbøl2
1Hearing Systems, Department of Health Technology, Technical University of Denmark, Kgs. Lyngby, Denmark.
In-situ audiometry, a simpler method for hearing aid fitting, shows accurate hearing threshold measurements comparable to conventional methods. This validates its use in remote hearing care, especially with open-fit hearing aids.
Area of Science:
- Audiology
- Hearing Science
- Medical Devices
Background:
- In-situ audiometry offers a resource-efficient alternative to conventional audiometry for hearing aid fitting.
- Previous studies raised concerns about its accuracy, particularly with open-fit hearing aids due to potential low-frequency leakage.
Purpose of the Study:
- To investigate the validity of in-situ audiometry for hearing aid fitting.
- To assess the accuracy of in-situ measurements compared to conventional methods across different hearing aid configurations.
Main Methods:
- Evaluated six receiver-in-canal hearing aids across three experiments.
- Measured hearing aid gain, recorded in-situ stimuli, and compared hearing thresholds using both in-situ and conventional audiometry in patients with open-fit hearing aids.
Main Results:
- Hearing aid gain was unaffected by the measurement method for open-fit devices.
- In-situ stimuli were adjusted below 1000 Hz for most open-fit hearing aids, suggesting the need for closed domes.
- Mean interparticipant threshold differences were within 5 dB for frequencies between 250 and 6000 Hz.
Conclusions:
- Modern in-situ audiometry thresholds closely align with conventional measurements.
- In-situ audiometry is a valid and promising tool for remote hearing care and hearing aid fitting.
More Related Videos
07:00Electrically Evoked Stapedius Reflex Measurements in Cochlear Implantation and Its Application in the Postoperative Fitting Process
Published on: June 21, 2024
03:58Enhancing Electrode Location Assessment in Cochlear Implantation via Computed Tomography Image Fusion
Published on: January 17, 2025
Related Concept Videos
Hearing
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Sum and Difference OpAmps
A summing amplifier, or an adder, utilizes an op-amp to merge multiple input signals into a single output signal. When audio signals are introduced into its input channels, the input resistors initiate currents that traverse feedback resistors, resulting in an output voltage. Applying Kirchhoff's current...
Characteristics of Practical Op Amps
The ratio of differential gain to the common-mode gain is defined as the common-mode rejection ratio (CMRR). This ratio quantifies the ability of operational amplifiers (op-amps) to reject common-mode...
Instrumentation Amplifier
To overcome this challenge, an ECG machine utilizes an instrumentation amplifier. This specialized amplifier is...
Electronic Distance Measuring Instruments