Dynamic Estimation of Cardiovascular State From Arterial Blood Pressure Recordings
Abstract:
Real-time estimation of patient cardiovascular states, including cardiac output and systemic vascular resistance, is necessary for personalized hemodynamic monitoring and management. Highly invasive measurements enable reliable estimation of these states but increase patient risk. Prior methods using minimally invasive measurements reduce patient risk but have produced unreliable estimates limited due to trade-offs in accuracy and time resolution. Our objective was to develop an approach to estimate cardiac output and systemic vascular resistance with both a high time resolution and high accuracy from minimally invasive measurements. Using the two-element Windkessel model, we formulated a state-space method to estimate a dynamic time constant - the product of systemic vascular resistance and compliance - from arterial blood pressure measurements. From this time constant, we derived proportional estimates of systemic vascular resistance and cardiac output. We then validated our method with a swine cardiovascular dataset. Our estimates produced using arterial blood pressure measurements not only closely align with those using highly invasive measurements, but also closely align when derived from three separate locations on the arterial tree. Moreover, our estimates predictably change in response to standard cardiovascular drugs. Overall, our approach produces reliable, real-time estimates of cardiovascular states crucial for monitoring and control of the cardiovascular system.
More Related Videos
Related Concept Videos
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pre-Procedural Guidelines for Assessing Blood Pressure
Measurement of Blood Pressure