Related Experiment Video
Updated: Jun 23, 2025

Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Rapid sequential determination of the explosives 2,4,6-trinitrotoluene and cyclotrimethylenetrinitramine in forensic
Sílvia V F Castro1, Jian F S Pereira1, Maria M C Souza1
1Chemistry Institute, Federal University of Uberlândia, Uberlândia, 38400-902, MG, Brazil.
Abstract:
The development of a portable analytical procedure is described for rapid sequential detection and quantification of the explosives 2,4,6-trinitrotoluene (TNT) and cyclotrimethylenetrinitramine (RDX) in forensic samples using a graphite sheet (GS). A single GS platform works as a collector of explosive residues and detector after its assembly into a 3D-printed cell. The detection strategy is based on cyclic square-wave stripping voltammetry. The cathodic scan from + 0.1 to -1.0 V with accumulation at 0.0 V enables the TNT detection (three reduction peaks), and the anodic scan from + 0.2 to + 1.55 V with accumulation at -0.9 V provides the RDX detection (two oxidation processes). Low detection limit values (0.1 µmol L-1 for TNT and 2.4 µmol L-1 for RDX) and wide linear ranges (from 1 to 150 µmol L-1 for TNT and from 20 to 300 µmol L-1 for RDX) were obtained. The sensor did not respond to pentaerythritol tetranitrate (PETN), which was evaluated as a potential interferent, because plastic explosives contain mixtures of TNT, RDX, and PETN. The GS electrode was also evaluated as a collector of TNT and RDX residues spread on different surfaces to simulate forensic scenarios. After swiping over different surfaces (metal, granite, wood, cloths, hands, money bills, and cellphone), the GS electrode was assembled in the 3D-printed cell ready to measure both explosives by the proposed method. In all cases, the presence of TNT and RDX was confirmed, attesting the reliability of the proposed device to act as collector and sensor.
More Related Videos
07:32Detection of 3-Nitrotyrosine in Atmospheric Environments via a High-performance Liquid Chromatography-electrochemical Detector System
Published on: January 30, 2019
05:31Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
Related Concept Videos
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Voltammetric Techniques: Cyclic Voltammetry
Voltammetric Techniques: Linear-Scan (E vs Time)
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Types of Detectors-II
High-Performance Liquid Chromatography: Types of Detectors