Multi-Modal Home Sleep Monitoring in Older Adults
Published on: January 26, 2019
[Home CPAP Remote Monitoring as a System to Control Adaptation and Titration in Obstructive Sleep Apnoea and its
María Teresa Ramírez Prieto1, M A Vaneas Lores Gutiérrez1, Raul Moreno Zabaleta1
1Servicio de Neumología. Hospital Universitario Infanta Sofía, San Sebastián de los Reyes, Madrid, España.
Introduction:
Continuous Positive Airway Pressure (CPAP) constitutes the most effective treatment for Obstructive Sleep Apnea (OSA). Automatic titration systems (ATS) are predominantly used to achieve adaptation to the equipment. Home CPAP devices allow telemonitoring (TM) of the same parameters as those provided by ATS but with access to continuous usage data. Under this premise, we conducted a study on the potential validity of TM for home CPAP devices as a titration system, its direct impact on proper adaptation (AD) to the equipment, and secondarily on the healthcare resources employed to achieve it.
Material And Methods:
An observational study involving 318 patients with OSA who were titrated using TM to achieve AD to CPAP. Patients with OSA were consecutively recruited and evaluated at 1, 3, and 6 months after initiating treatment. Results were compared with a historical group of 307 patients with OSA who achieved AD to CPAP using ATS. Additionally, we assessed the impact on required healthcare resources.
Results:
Patients with OSA who initiated CPAP treatment with TM over the first six months showed a similar AD rate compared to the historical group titrated using ATS, with lower resource usage in the TM group.
Conclusion:
Data provided by TM of home CPAP devices allow for titration and achieving similar AD as with ATS in non-complex patients.
Related Concept Videos
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Sleep Apnea
The condition is more prevalent among...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...