Related Experiment Video
Updated: Jun 23, 2025

Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera
Published on: January 30, 2020
A survey of gamma camera and SPECT/CT quality control programs across a sample of public hospitals in Australia
Nirvadesh Ramkishore1, James Crocker2, Ruth Martin2
1Department of Radiology and Nuclear Medicine, Alfred Health, Melbourne, VIC, Australia. n.ramkishore@alfred.org.au.
Abstract:
Performance testing of gamma cameras and single photon computed tomography/computed tomography (SPECT/CT) systems is not subject to regulatory requirements across states and territories in Australia. Internationally recognised testing standards from organisations such as the National Electrical Manufacturers Association (NEMA) describe methodologies for recommended tests. However, variations exist in suggested quality control (QC) schedules from professional bodies such as the Australia and New Zealand Society of Nuclear Medicine (ANZSNM). In this study, a survey was conducted to benchmark current QC programs across a selected sample of eight standalone and networked Australian public hospitals. Vendor-specific flood-field uniformity (intrinsic or extrinsic/system) verification without photomultiplier (PMT) tuning and CT QC were performed at all sites. Weekly and monthly PMT tuning followed by intrinsic flood-field verifications were performed at most sites. At least half of the sites performed monthly centre of rotation (COR) offset verifications. SPECT/CT alignment calibrations and verifications were undertaken by service engineers at all sites, and periodic verifications were performed by local staff at varying frequencies. Variations were observed for other periodic QC tests such as spatial resolution and planar sensitivity. Similarly, variations were observed for tests specific to whole-body systems and SPECT systems. Most sites checked daily and periodic QC results against pass/fail criteria set by vendors. Additional analyses of the QC results, including trend analysis and periodic reviews, were not common practice. The lack of regulatory requirements is likely to have led to variations in QC tests that are generally either harder to perform or are more labour intensive.
More Related Videos
09:55Radiosynthesis, Quality Control, and Small Animal Positron Emission Tomography Imaging of 68Ga-Labelled Nano Molecules
Published on: October 4, 2024
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Radiological Investigation I: X-ray and CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...