Engagement in mHealth-Prompted Self-Measured Blood Pressure Monitoring Among Participants Recruited From a Safety-Net
Lesli E Skolarus1, Chun Chieh Lin2, Sonali Mishra3
1Department of Neurology, Stroke and Vascular Neurology, Northwestern University, Chicago, IL, United States.
Background:
Hypertension, a key modifiable risk factor for cardiovascular disease, is more prevalent among Black and low-income individuals. To address this health disparity, leveraging safety-net emergency departments for scalable mobile health (mHealth) interventions, specifically using text messaging for self-measured blood pressure (SMBP) monitoring, presents a promising strategy. This study investigates patterns of engagement, associated factors, and the impact of engagement on lowering blood pressure (BP) in an underserved population.
Objective:
We aimed to identify patterns of engagement with prompted SMBP monitoring with feedback, factors associated with engagement, and the association of engagement with lowered BP.
Methods:
This is a secondary analysis of data from Reach Out, an mHealth, factorial trial among 488 hypertensive patients recruited from a safety-net emergency department in Flint, Michigan. Reach Out participants were randomized to weekly or daily text message prompts to measure their BP and text in their responses. Engagement was defined as a BP response to the prompt. The k-means clustering algorithm and visualization were used to determine the pattern of SMBP engagement by SMBP prompt frequency-weekly or daily. BP was remotely measured at 12 months. For each prompt frequency group, logistic regression models were used to assess the univariate association of demographics, access to care, and comorbidities with high engagement. We then used linear mixed-effects models to explore the association between engagement and systolic BP at 12 months, estimated using average marginal effects.
Results:
For both SMBP prompt groups, the optimal number of engagement clusters was 2, which we defined as high and low engagement. Of the 241 weekly participants, 189 (78.4%) were low (response rate: mean 20%, SD 23.4) engagers, and 52 (21.6%) were high (response rate: mean 86%, SD 14.7) engagers. Of the 247 daily participants, 221 (89.5%) were low engagers (response rate: mean 9%, SD 12.2), and 26 (10.5%) were high (response rate: mean 67%, SD 8.7) engagers. Among weekly participants, those who were older (>65 years of age), attended some college (vs no college), married or lived with someone, had Medicare (vs Medicaid), were under the care of a primary care doctor, and took antihypertensive medication in the last 6 months had higher odds of high engagement. Participants who lacked transportation to appointments had lower odds of high engagement. In both prompt frequency groups, participants who were high engagers had a greater decline in BP compared to low engagers.
Conclusions:
Participants randomized to weekly SMBP monitoring prompts responded more frequently overall and were more likely to be classed as high engagers compared to participants who received daily prompts. High engagement was associated with a larger decrease in BP. New strategies to encourage engagement are needed for participants with lower access to care.
Related Concept Videos
Errors occurring during blood pressure monitoring
Several factors...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Pre-Procedural Guidelines for Assessing Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of blood pressure in brachial artery(two-step method)
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement