Analysis of Different Early Strength Agents on the Performance of Prefabricated UHPC
Xiaohu Wu1,2, Lien Hu3,4, Fucheng Guo1,5
1School of Civil Engineering, Lanzhou Jiaotong University, Lanzhou 730070, China.
Abstract:
Precast ultra-high-performance concrete (UHPC) has emerged as indispensable in the engineering sector due to its cost-effectiveness and superior performance. Currently, precast UHPC grapples with challenges pertaining to slow setting times and insufficient early strength, largely attributed to its high water-reducing agent content. Effective utilization of early strength agents to augment UHPC's early strength is pivotal in addressing this issue. This study investigates the efficacy of two distinct concrete early strength agents, namely calcium formate (Ca(HCO2)2) and aluminum sulfate (Al2(SO4)3). A UHPC system with a water/cement ratio of 0.17 was used; both single and compound doping experiments were conducted using varied dosages of the aforementioned early strength agents. Our results show that both early strength agents significantly reduce setting time and enhance early strength at appropriate dosages. Specifically, the addition of 0.3% Ca(HCO2)2 led to a 33.07% decrease in setting time for UHPC. Moreover, the incorporation of 0.3% Ca(HCO2)2 and 0.5% Al2(SO4)3 resulted in a strength of 81.9 MPa at 1.5 days, representing a remarkable increase of 118.4%. It is noteworthy that excessive use of Ca(HCO2)2 inhibits the hydration process, whereas an abundance of Al2(SO4)3 diminishes the early strength effect. Simultaneously, this article provides recommendations regarding the dosage of two distinct early strength agents, offering a novel solution for expediting the production of prefabricated UHPC with a low water/cement ratio and high water-reducing agent content.
More Related Videos
06:02Disentangling High Strength Copolymer Aramid Fibers to Enable the Determination of Their Mechanical Properties
Published on: September 1, 2018
07:15A Testing Platform for Durability Studies of Polymers and Fiber-reinforced Polymer Composites under Concurrent Hygrothermo-mechanical Stimuli
Published on: December 11, 2014
Related Concept Videos
Prestressed Concrete
Fiber Reinforced Concrete
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Reinforcements in Concrete
Accelerators
The effectiveness of calcium chloride can...
Bonding and Strength of Aggregate