Objectives:
In remodeling valve-sparing root replacement with external annuloplasty, we compare long-term outcomes of a calibrated expansible extra-aortic ring with a homemade Dacron ring.
Methods:
All patients (2003-2020) operated for root aneurysm with/without aortic insufficiency (AI) were included. The standardized CAVIAAR (conservation aortique valvulaire dans les insuffisances aortiques et anévrysmes de la racine-Valve sparing in aortic insufficiencies and root aneurysms) technique was root remodeling and external annuloplasty ring with the EXTRA-AORTIC Ring or homemade Dacron ring.
Results:
Among 486 patients (age 52.3 ± 14.0 years) operated for root aneurysm, 375 (repair rate: 77.1%) underwent root remodeling with annuloplasty (extra-aortic ring, n = 289, vs Dacron ring, n = 86). At 10 years (median follow-up, 4.08 years' interquartile range, 1.95-7.61), unmatched and matched analysis showed that patients with extra-aortic ring had greater survival, similar to the general population (93.3% vs 79.9%, P = .097), lower reoperation incidence (2.0% vs 9.7%, P = .0098), and lower AI grade >2 recurrence (1.9% vs 11.2%, P = .0042), compared with patients with a Dacron ring. Mixed-effect model showed that with extra-aortic ring annuloplasty, annular dilation over time (P = .0033) was prevented and, compared with the homemade Dacron ring, root expansibility was better preserved (3.22% vs 2.12%, P = .002) and mean transvalvular gradient was lower (6.58 mm Hg vs 7.94 mm Hg, P = .001). Tricuspid and bicuspid valves with extra-aortic ring had similar reoperation (4.3% vs 0.85%, P = .65) and AI grade >2 incidence (2.7% vs 1.2%, P = .61), expansibility (P = .29), and diameter (P = .47), whereas mean transvalvular gradient was lower for tricuspid valves (5.58 mm Hg vs 7.60 mm Hg, P = .004).
Conclusions:
Valve-sparing root remodeling with calibrated expansible extra-aortic ring annuloplasty improves the outcomes of reoperation and recurrent AI compared with a homemade Dacron ring. It prevents dilation and maintains physiological root dynamics for durable valve repair.