Noninvasive Temperature Measurements in Tissue-Simulating Phantoms Using a Solid-State Near-Infrared Sensor
Ariel Kauffman1, John Quan Nguyen1, Sanjana Parthasarathy1
1Rockley Photonics Inc., Irvine, CA 92614, USA.
Abstract:
The monitoring of body temperature is a recent addition to the plethora of parameters provided by wellness and fitness wearable devices. Current wearable temperature measurements are made at the skin surface, a measurement that is impacted by the ambient environment of the individual. The use of near-infrared spectroscopy provides the potential for a measurement below the epidermal layer of skin, thereby having the potential advantage of being more reflective of physiological conditions. The feasibility of noninvasive temperature measurements is demonstrated by using an in vitro model designed to mimic the near-infrared spectra of skin. A miniaturizable solid-state laser-diode-based near-infrared spectrometer was used to collect diffuse reflectance spectra for a set of seven tissue phantoms composed of different amounts of water, gelatin, and Intralipid. Temperatures were varied between 20-24 °C while collecting these spectra. Two types of partial least squares (PLS) calibration models were developed to evaluate the analytical utility of this approach. In both cases, the collected spectra were used without pre-processing and the number of latent variables was the only optimized parameter. The first approach involved splitting the whole dataset into separate calibration and prediction subsets for which a single optimized PLS model was developed. For this first case, the coefficient of determination (R2) is 0.95 and the standard error of prediction (SEP) is 0.22 °C for temperature predictions. The second strategy used a leave-one-phantom-out methodology that resulted in seven PLS models, each predicting the temperatures for all spectra in the held-out phantom. For this set of phantom-specific predicted temperatures, R2 and SEP values range from 0.67-0.99 and 0.19-0.65 °C, respectively. The stability and reproducibility of the sample-to-spectrometer interface are identified as major sources of spectral variance within and between phantoms. Overall, results from this in vitro study justify the development of future in vivo measurement technologies for applications as wearables for continuous, real-time monitoring of body temperature for both healthy and ill individuals.
More Related Videos
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...