Double closed loop PI control with full compensation arc elimination based on zero sequence voltage of neutral point
Hongwen Liu1,2, Xiangjun Zeng3, Qing Yang4
1State Key Laboratory of Power Transmission Equipment and System Security and New Technology, Chongqing University, Chongqing, 400044, China. liuhongwen_19@163.com.
This study introduces a dual closed-loop PI control method to improve arc suppression during grounding faults in power systems. The new method effectively stabilizes residual voltage, ensuring reliable arc extinction.
Area of Science:
- Electrical Engineering
- Power Systems Analysis
- Fault Detection and Mitigation
Background:
- Grounding faults in power systems generate zero-sequence voltage due to unbalanced parameters, negatively impacting arc suppression.
- Existing arc suppression methods struggle with the effects of unbalanced parameters under various grounding modes.
- Controllable voltage sources offer potential for improved arc suppression but require precise control strategies.
Purpose of the Study:
- To analyze the influence of ground unbalance parameters on arc suppression effectiveness.
- To reveal the mechanism of full compensation arc suppression using neutral point zero-sequence voltage.
- To develop and validate a novel control model for enhanced arc suppression during grounding faults.
Main Methods:
- Analysis of ground unbalance parameters and their effect on controllable voltage source arc suppression.
- Development of a fully compensated arc suppression model using a dual closed-loop Proportional-Integral (PI) controller.
- Implementation of control strategies based on neutral point voltage deviation and fault phase residual voltage.
Main Results:
- The dual closed-loop PI control algorithm effectively stabilizes the controllable voltage source output waveform.
- Residual voltage stabilization times were significantly improved compared to traditional methods, ranging from 43 ms to 2.4 s.
- The proposed method consistently reduced residual voltage in the grounded fault phase to below 10 V, ensuring reliable arc extinction.
Conclusions:
- The developed dual closed-loop PI control method offers a robust solution for arc suppression in grounding faults.
- This approach enhances the stability and reliability of power systems by ensuring effective arc extinction.
- Simulation and low-voltage tests confirm the algorithm's feasibility and effectiveness.
Related Concept Videos
Time and frequency -Domain Interpretation of PI Control
Acting as a low-pass filter, the PI controller slows the system's response and extends settling times. This requires...
PI Controller: Design
Open and closed-loop control systems
An open-loop control system operates without feedback from the output. It consists of two primary elements: the controller and the controlled process. The controller receives an input signal...
PID Controller
Control System Problem
When forming a closed-loop system, issues can arise if the poles cross into the unstable region, leading to potential...
Line Protection with Impedance Relays
Under normal conditions, low load currents keep the measured...