Rejection of Fluorescence Background in Resonance and Spontaneous Raman Microspectroscopy
Published on: May 18, 2011
High-Throughput Raman Spectroscopy by Horizontally Shifted Collection Fibers
Koseki J Kobayashi-Kirschvink1,2, Alex Matlock1, Peter T C So1
1Laser Biomedical Research Center, G. R. Harrison Spectroscopy Laboratory, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, United States.
Abstract:
Optical fiber probe-based Raman spectroscopy systems are widely used for in situ measurements ranging from material characterization to biomedical applications. However, small Raman cross sections necessitate the use of high-power lasers or long exposure times that limit Raman's larger application to multiple research fields. This limitation can be overcome by collecting more Raman photons through additional collection fibers with taller detectors. This system configuration requires replacement of the detector and modification of the spectrograph to incorporate larger optical components, making it a costly and cumbersome option. In probe-based Raman systems, a typical detector image shows stacked collection fibers on the vertical axis and Raman spectra on the horizontal axis. While the vertical pixels are fully packed with multiple collection fibers, horizontal pixels have broad silent regions due to the narrow bandwidth of Raman peaks, potentially wasting valuable detector pixels. Here, we propose a new approach utilizing horizontally shifted collection fibers rather than vertically stacked ones. We designed and fabricated a novel collection fiber bundle that has horizontally shifted optical fibers in two vertical lines at the spectrograph entrance. This custom-made fiber bundle was incorporated into the imaging spectrograph to provide multiple horizontally shifted spectra on the detector. Through deconvolution, the original spectra can be recovered with an improved detection limit from greater photon collection. We demonstrate an enhanced limit of detection on various bioanalytes, such as glucose, urea, and lactate. Further, we applied the probe to measure tissue Raman spectra and successfully decomposed them into basis spectra, demonstrating the potential application of high-throughput in vivo tissue diagnosis. Our approach provides a simple, cost-effective, and universal method to increase the throughput without modifying existing Raman spectrometers.
Related Concept Videos
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...