Subcostal Specimen Removal in Completely Portal Robotic Lobectomy
Published on: April 19, 2024
292
Robotic Lobectomy with a Single Robotic Stapler from One 12-mm Port: A Multi-institutional Study
Yoshimasa Inoue1, Koichi Fujiu2, Tetsuya Endo3
1Department of General Thoracic Surgery, Saiseikai Yokohama-shi Tobu Hospital, Yokohama, Japan.
The Keio Journal of Medicine
|July 28, 2024
Summary
Robotic lobectomy using a single type of stapler through one 12-mm port is feasible. This approach simplifies procedures, potentially reduces postoperative pain, and lowers inventory costs for robotic surgery.
Area of Science:
- Thoracic Surgery
- Minimally Invasive Surgery
- Robotic Surgery
Background:
- Robotic lobectomy offers autonomy but uses larger 12-mm ports, increasing postoperative pain risk.
- Using two 12-mm ports is common for optimal surgical angles, yet increases instrument inventory and complexity.
- Simplifying procedures and reducing costs are key goals in robotic surgery.
Purpose of the Study:
- To assess the feasibility of robotic lobectomy using a single type of stapler (SureForm45 Curved-Tip) via one 12-mm port.
- To investigate the cost-effectiveness of using an additional 60-mm stapler for interlobar division compared to the single stapler approach.
Main Methods:
- A multicenter study involving 135 robotic lobectomy cases.
- Utilized a single type of robotic stapler, SureForm45 Curved-Tip (SF45C), inserted through a single 12-mm port.
- Analyzed stapling procedures and compared costs associated with using additional staplers for interlobar division.
Main Results:
- All stapling procedures were successfully completed using the SF45C from the single 12-mm port in all 135 cases.
- Using an additional 60-mm stapler was potentially cost-effective only if more than six SF45C reloads were needed for interlobar division.
- This specific cost-saving scenario occurred in only one case (0.7%).
Conclusions:
- Robotic lobectomy with a single type of stapler inserted via one 12-mm port is technically feasible.
- This approach can simplify surgical procedures and potentially minimize postoperative pain.
- Reduced instrument inventory and associated costs are potential benefits of this streamlined technique.