Related Experiment Video
Updated: Jun 23, 2026

Accurate and Simple Evaluation of Vascular Anastomoses in Monochorionic Placenta using Colored Dye
Published on: September 5, 2011
Quantifying placenta accreta spectrum severity and its associated blood loss: a novel transvaginal ultrasound scoring
Neha Agarwal1, Edgar Hernandez-Andrade1, Baha M Sibai2
1Division of Fetal Intervention, Department of Obstetrics, Gynecology and Reproductive Sciences, UTHealth McGovern Medical School, Houston, TX (Agarwal, Hernandez-Andrade, Backley, Johnson, Espinoza, Bergh, Zhu, Salazar, and Papanna).
Background:
Hemorrhage associated with placenta accreta spectrum (PAS) is a leading cause of maternal morbidity and mortality. Estimating blood loss in these individuals is a critical component of comprehensive preoperative planning.
Objective:
A semiquantitative score based on transvaginal ultrasound was developed and tested to predict PAS, estimate its severity, and blood loss in individuals with clinical and ultrasound evidence suggesting PAS.
Study Design:
A secondary analysis was conducted of prospectively collected data from a quaternary center of patients with suspected accreta on 2D ultrasound and clinical suspicion. A predetermined scoring system was applied based on three components: (1) uterine wall (score 0: no loss of hypo-translucent uterine wall with overlying placenta in the lower uterine segment; 1: loss of hypo-translucent <3-cm defect; 2: 3-6-cm defect; and 3: >6-cm defect); (2) arterial vascularity at the uterine wall defect (score 0: no vessels observed; 1: 1-2 vessels over the defect; 2: 3-5 vessels; and 3: >5 vessels); and (3) cervical involvement (score 0: normal cervical length without previa; 1: previa with normal cervical length; 2: short cervix with previa, minimal vascularity and small lacunae; 3: short cervix with previa, increased vascularity and large lacunae). Each patient's three domain scores determined a cumulative, final score of 0-9. Patients were managed at the discretion of a multi-disciplinary team and patient's preference among the following options: cesarean delivery with placenta removal, cesarean delivery with placenta in-situ (conservative) with or without delayed hysterectomy, or cesarean hysterectomy. The frequency of different degrees of placental invasion per pathology examination per score unit was registered. Multiple linear regression analysis was performed for association of blood loss according to score adjusted by risk factors for PAS.
Results:
A total of 73 patients were evaluated. All 11 patients who had a score of 0 had cesarean delivery with placenta removal without evidence of intraoperative PAS, thus resulting in a 100% negative predictive value. The remaining 62 had scores between 1 and 9. Among patients with scores 0-3 (n=20), only one had intraoperative PAS, yielding a negative predictive value of 97%. Higher scores were associated with severe PAS forms (r=0.301, P=.02). Based on the associations between PAS scores, clinical correlation, and blood loss, we divided patients into four categories: Category 0: PAS score 0; Category 1: scores 1-3; Category 2: scores 4-6; and Category 3: scores 7-9. The median blood loss in Category 0=635±352 mL, Category 1=634±599 mL, Category 2=1549±1284 mL, and Category 3=1895±2106 mL (P<.001). On multivariable analysis, Category 2 (β=0.97, P<.01) and Category 3 (β=1.26, P<.003) were associated with significantly greater blood loss than Category 0, irrespective of type of surgery.
Conclusion:
The transvaginal ultrasound score separates groups at low risk (Category 0) and at higher risk of PAS (Categories 1-3). Categories 1-3 may provide important clinical information to estimate the risk of severe forms of PAS and of blood loss during surgery. VIDEO ABSTRACT.
More Related Videos
12:17The 4-vessel Sampling Approach to Integrative Studies of Human Placental Physiology In Vivo
Published on: August 2, 2017
09:51Model Surgical Training: Skills Acquisition in Fetoscopic Laser Photocoagulation of Monochorionic Diamniotic Twin Placenta Using Realistic Simulators
Published on: March 21, 2018
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: