Reliability of Surface Electromyography From the Lower-limb Muscles During Maximal and Submaximal Voluntary Isometric
Yong Hur1, Byung-Mo Oh1,2, Han Gil Seo1
1Department of Rehabilitation Medicine, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Korea.
Abstract:
This study aims to develop maximal voluntary isometric contraction (MVIC) and submaximal voluntary isometric contraction (subMVIC) methods and to assess the reliability of the developed methods for in-bed healthy individuals and patients with subacute stroke. The electromyography (EMG) activities from the lower-limb muscles including the tensor fascia lata (TFL), rectus femoris (RF), tibialis anterior (TA), and gastrocnemius (GC) on both sides were recorded during MVIC and subMVIC using surface EMG sensors in 20 healthy individuals and 20 subacute stroke patients. In inter-trial reliability, both MVIC and subMVIC methods demonstrated excellent reliability for all the measured muscles at baseline and follow-up evaluations in both healthy individuals and stroke patients. In inter-day reliability, MVIC showed good reliability for the TFL and moderate reliability for the RF, TA, and GC, while subMVIC showed good reliability for the TFL, RF, and GC and poor reliability for the TA in healthy individuals. In conclusion, the MVIC and subMVIC methods of EMG activities were feasible in in-bed healthy individuals and patients with subacute stroke. The results can serve as a basis for the clinical evaluation of muscular activities using quantitative EMG signals on the lower-limb muscles in stroke patients with impaired mobility.
More Related Videos
07:53Assessment of Neuromuscular Function Using Percutaneous Electrical Nerve Stimulation
Published on: September 13, 2015
08:40Isokinetic Robotic Device to Improve Test-Retest and Inter-Rater Reliability for Stretch Reflex Measurements in Stroke Patients with Spasticity
Published on: June 12, 2019
Related Concept Videos
Pulse Assessment Sites
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Pulse
The pulse serves as a clinical indicator...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...