Related Experiment Video
Updated: Jun 17, 2025

Doppler Optical Coherence Tomography of Retinal Circulation
Published on: September 18, 2012
Validity and Reliability of 2 Cirrus Optical Coherence Tomography Procedures for Measuring Objective Ocular Torsion
Elena Piedrahita-Alonso1, Estela López-Redondo1, Alicia Valverde-Megías2
1From the Faculty of Optics and Optometry, Complutense University of Madrid, Madrid, Spain (E-P.A., E.L-R., B.M-G., R.G-L.).
The disc-fovea angle (DFA) measured by Cirrus HD-OCT is a valid and reliable method for assessing cycloposition in normal patients. The Cirrus OCT HD 1 line scan offers the best clinical performance due to its speed and simplicity.
Area of Science:
- Ophthalmology
- Medical Imaging
- Strabismus Research
Background:
- Torsional eye position, quantified by the disc-fovea angle (DFA), is a crucial objective parameter in diagnosing and managing vertical strabismus.
- Optical coherence tomography (OCT) offers a promising alternative to traditional fundus photography for DFA measurement.
- Existing OCT methods require further validation for clinical application in objective cycloposition assessment.
Purpose of the Study:
- To analyze the validity and reliability of two novel Cirrus high-definition OCT (HD-OCT) methods for measuring objective cycloposition.
- To compare the performance of Cirrus HD-OCT methods against Spectralis spectral-domain OCT and fundus photography (gold standard).
- To identify OCT methods offering clinical advantages in speed and simplicity for DFA measurement.
Main Methods:
- A prospective study involving 59 normal individuals, measuring DFA using fundus photography, Spectralis OCT (FoDi software), Cirrus HD-OCT (1-line scan), and Cirrus HD-OCT (macular cube).
- Each method was applied three times per participant, with repositioning between captures to ensure reliability.
- Manual quantification by two independent observers was performed for fundus photography and Cirrus cube methods.
Main Results:
- All three Cirrus HD-OCT methods demonstrated excellent agreement with fundus photography (Intraclass Correlation Coefficient [ICC] 0.83-0.84) with no significant mean value differences.
- Excellent reliability was observed across all tested methods (ICC 0.91-0.92), with minimal detectable change below 3° and absolute differences of 1° between repeated measurements.
- Inter-rater reliability was excellent for manual quantification methods (ICC 0.98 for cube, 0.94 for fundus).
Conclusions:
- Cirrus HD-OCT methods provide a valid and reliable alternative for assessing cycloposition via DFA measurement in normal patients.
- The Cirrus OCT HD 1-line scan method emerged as the most clinically advantageous due to its straightforward and rapid measurement process.
- The simplicity and speed of the Cirrus OCT HD 1-line scan eliminate the need for image export, enhancing clinical workflow efficiency.
More Related Videos
07:44In vivo Structural Assessments of Ocular Disease in Rodent Models using Optical Coherence Tomography
Published on: July 24, 2020
07:08Using Optical Coherence Tomography and Optokinetic Response As Structural and Functional Visual System Readouts in Mice and Rats
Published on: January 10, 2019