Acute increase in pacing capture threshold and impedance post-leadless pacemaker implant with spontaneous resolution

Jian Liang Tan1, Andrew E Epstein1, Timothy M Markman1

  • 1Section of Electrophysiology, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania.

Heartrhythm Case Reports
|August 12, 2024
PubMed
Abstract

No abstract available in PubMed .

Keywords:
Capture thresholdCardiac implantable electronic deviceDevice thrombusImpedanceLeadless pacemaker

More Related Videos

Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
12:45

Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing

Published on: December 11, 2017

10.5K
A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation
16:40

A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation

Published on: February 28, 2012

26.2K

Related Experiment Videos

Last Updated: Jun 17, 2025

Translational Rabbit Model of Chronic Cardiac Pacing
06:14

Translational Rabbit Model of Chronic Cardiac Pacing

Published on: January 6, 2023

2.5K
Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
12:45

Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing

Published on: December 11, 2017

10.5K
A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation
16:40

A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation

Published on: February 28, 2012

26.2K

Related Concept Videos

Pulse rhythm01:30

Pulse rhythm

777
Pulse rhythm refers to the pattern of pulsations within specific intervals, offering valuable insights into the regularity or irregularity of the heart's beats as observed through the pattern of pulsation within specific intervals. A regular pulse exhibits a consistent heart rate with uniform waveforms and pulsation force, variations of which can be classified as normal, weak, or bounding.
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
777
Electrophysiology of Normal Cardiac Rhythm01:19

Electrophysiology of Normal Cardiac Rhythm

2.6K
The normal cardiac rhythm is a synchronized electrical activity that facilitates the regular and coordinated contraction of the heart muscle. This process is essential for efficient blood circulation throughout the body. The fundamental elements involved in establishing and maintaining this rhythm include the unique electrical properties of cardiac muscle cells, the sinoatrial (SA) node's pacemaker function, the specialized conducting system, and the ionic mechanisms underlying each phase...
2.6K

Articles linked to this work by shared authors, journal, and citation graph.

Clinical characteristics of multifocal premature ventricular complexes originating from the basal septal region of the left ventricle: Anatomy, mapping, and ablation.

Heart rhythm·2026

Ventricular Arrhythmia Ablation in Inherited Cardiomyopathy: Phenotype Variability and Outcomes Based on Functional Genotypes.

Journal of the American Heart Association·2026

Transhepatic Access for Pulsed Field Ablation of Atrial Fibrillation Using a Dual-Energy Lattice-Tip Catheter.

JACC. Case reports·2026

Physiological Markers of Effective Autonomic Denervation Are Associated With Outcomes After Cardioneuroablation for Vasovagal Syncope.

JACC. Clinical electrophysiology·2026

Intraseptal Mapping of Premature Ventricular Complexes Using Multipolar Catheters.

JACC. Clinical electrophysiology·2026

Quantitative Vector Screening to Improve Sensing and Reduce Inappropriate Shocks With the Subcutaneous Implantable Cardioverter Defibrillator.

Circulation. Arrhythmia and electrophysiology·2026

Self-sustaining leadless intracardiac pacemaker powered by triboelectric nanogenerator.

Science advances·2026

Stepwise Electrosurgical Bailout During Difficult Left Bundle Branch Area Pacing.

Pacing and clinical electrophysiology : PACE·2026

Conduction Disturbances and Permanent Pacemaker Implantation After TAVR With Self-Expanding Devices: The CONNAVIPRO Study.

Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions·2026

Magnetic Field-Modulated Ion Migration in Electrochemical Cells.

Chemphyschem : a European journal of chemical physics and physical chemistry·2026

Can distinguishing regenerative braking signal in electric vehicles improve following-vehicle safety?

Accident; analysis and prevention·2026

Mechanically-induced fiducial marker system for event-based synchronization of independent recording instruments.

Measurement science & technology·2026
See all related articles
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies
Jove
Visualize
Contact Us