Related Experiment Video
Updated: Jun 17, 2025

A Minimally Invasive Model to Analyze Endochondral Fracture Healing in Mice Under Standardized Biomechanical Conditions
Published on: March 22, 2018
Does the proximal screw type affect stress and strain in pastern arthrodesis with locking plate in horses?
Anderson Fernando de Souza1, César Augusto Martins Pereira2, Anton Fürst3
1Department of Surgery, School of Veterinary Medicine and Animal Science, University of São Paulo, São Paulo, Brazil.
Abstract:
The implantation of unicortical cortex screws in the proximal hole of locking compression plates (LCP) has been recommended for proximal interphalangeal (PIP) arthrodesis in horses to prevent fractures resulting from stress risers in the proximal phalanx (P1). However, this cortex screw fixation technique may limit efficient dorsal compression of the PIP joint by the plate, potentially affecting the stability of the construct. In this study, we aimed to measure stress and strain in P1 and the plate using an ex vivo model of PIP arthrodesis in horses. We employed various implantation methods and proximal screw types in conjunction with two 5.5 mm transarticular cortex screws. Ten pairs of equine forelimbs were divided into four groups based on proximal screw placement: GUC (unicortically placed cortex screw), GBC (bicortically placed cortex screw), GUL (unicortically placed locking screw), and GBL (bicortically placed locking screw). We calculated the magnitude and direction of strain, strain ratio, and stress using strain gauges during an axial compression mechanical testing. The palmar surface of P1 exhibited higher stress and strains than the dorsal surface, with the plate part located at the articular level suffered more stress than the proximal part. Both the implantation method and proximal screw type significantly influenced the analyzed parameters. The GUC promoted greater changes in strain direction in the proximal portion of the P1. Bicortical placement of a cortex screw appears to be the most suitable option for filling the proximal hole of the LCP, because it allows effective dynamic compression via the plate and prevents abrupt shifts in the direction of the forces acting on the proximal part of P1 during loading.
More Related Videos
07:41An Intramedullary Locking Nail for Standardized Fixation of Femur Osteotomies to Analyze Normal and Defective Bone Healing in Mice
Published on: November 13, 2016
06:38Establishment of a Segmental Femoral Critical-size Defect Model in Mice Stabilized by Plate Osteosynthesis
Published on: October 12, 2016