A case of atypical IgA paraprotein interference on multiple chemistry assays: How to deal with it
1Drs. Tribedi Roy Diagnostic Laboratory, Kolkata, India.
This case report discusses how paraproteins interfere with multiple chemistry analyses and protocols to overcome such obstacles. A serum specimen containing two monoclonal IgA (llight chain) paraproteins is subjected to a battery of tests on three wet chemistry platforms - AU5800, Cobas Pure, and Alinityci; the results were compared with those on a Vitros 350/ ECiQ dry chemistry platform. Paraprotein interference was found to affect the bilirubins, inorganic phosphate, and iron, whose repeat runs were also found to be irreproducible. Dilution with normal saline also failed to produce a satisfactory effect. Deproteinization by polyethylene glycol and dilution of the specimen with a normal serum specimen were observed to produce desirable results. Interference by IgA paraprotein on measurement of the bilirubin, phosphate, and iron in the wet chemistry system can be mitigated either by deproteinization or by dilution with normal serum.
This case report discusses how paraproteins interfere with multiple chemistry analyses and protocols to overcome such obstacles. A serum specimen containing two monoclonal IgA (llight chain) paraproteins is subjected to a battery of tests on three wet chemistry platforms - AU5800, Cobas Pure, and Alinityci; the results were compared with those on a Vitros 350/ ECiQ dry chemistry platform. Paraprotein interference was found to affect the bilirubins, inorganic phosphate, and iron, whose repeat runs were also found to be irreproducible. Dilution with normal saline also failed to produce a satisfactory effect. Deproteinization by polyethylene glycol and dilution of the specimen with a normal serum specimen were observed to produce desirable results. Interference by IgA paraprotein on measurement of the bilirubin, phosphate, and iron in the wet chemistry system can be mitigated either by deproteinization or by dilution with normal serum.
More Related Videos
Related Concept Videos
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Enzyme-Linked Immunosorbent Assay
There are many different types of ELISAs, but they all involve an antibody molecule whose constant region binds an enzyme, leaving the variable region free to bind its specific antigen. Enzyme-substrate reaction allows the antigen to be visualized or...