Purpose:
Patients who were administered radiopharmaceuticals can be a source of radiation exposure to sonographers. This study aimed to identify factors associated with radiation exposure to breast sonographers from patients administered radiopharmaceuticals for bone scanning.
Methods:
The exposure dose of six sonographers was measured during breast sonography in 59 patients administered 99mTc-HMDP. We predicted the following factors to be related to exposure dose: time interval between administration and sonography, sonography examination time, estimated radioactivity at sonography, sonographer's years of experience, and patients' clinical data (age, renal function and surgical procedure). Spearman's rank correlation coefficient was used to examine the relationship between radiation dose and the aforementioned factors.
Results:
The mean±standard deviation of the exposure dose for the sonographers was 9.3±3.8 µSv. The time interval between administering the radiopharmaceutical agent and sonography, the sonography examination time and estimated radioactivity at sonography were found to be factors related to the exposure of the sonographer. The exposure dose increased as a function of the shorter time interval, longer examination time and higher estimated radioactivity at sonography.
Conclusion:
The time interval between drug administration and sonography, sonography examination time and estimated radioactivity at sonography contributed to the increased dose to breast sonographers. Although we considered that the exposure dose of sonographers would not possibly exceed the dose limit in the present study, we suggested that radiological technologists need to educate the physicians requesting sonography, and the sonographers about the radiation exposure in nuclear medicine.
More Related Videos
09:07Multi-Tracer Studies of Brain Oxygen and Glucose Metabolism Using a Time-of-Flight Positron Emission Tomography-Computed Tomography Scanner
Published on: June 7, 2024
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
Related Concept Videos
Radiological Investigation I: X-ray and CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Magnetic Resonance Imaging