Related Experiment Video
Updated: Jun 16, 2025

MR Molecular Imaging of Prostate Cancer with a Small Molecular CLT1 Peptide Targeted Contrast Agent
Published on: September 3, 2013
Evaluating the Added Value of Concurrent Contrast-enhanced Diagnostic CT for PSMA-PET/CT Interpretation
Kelly Trinh1, David Z Chow2, Hyesun Park3
1Texas Tech University Health Sciences Center, School of Medicine, Lubbock, TX 79430; Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, Massachusetts General Hospital, Boston, MA 02114.
Rationale And Objectives:
To determine whether concurrent contrast-enhanced diagnostic CT (DxCT) confers added diagnostic certainty compared to PSMA-PET/CT alone.
Materials And Methods:
This retrospective multi-reader study analyzed imaging comprising combined F-18-piflufolastat PSMA-PET/CT with diagnostic chest/abdominopelvic CT from prostate cancer patients within the first 6 months of FDA-approval of the PET agent. Six nuclear radiology readers were randomly presented with PSMA-PET/CT studies with or without DxCT and asked to report their diagnostic certainty for PSMA-avid lesions found on PET. Subsequently, readers re-reviewed the same study after an interlude (with the CT if not previously presented and vice-versa) to determine if DxCT altered their diagnostic assessment. Inter-rater concordance was assessed on a subset of images read by all readers. Diagnostic certainties for PSMA-PET/CT with and without DxCT were compared, and the variables for which DxCT may add value were examined.
Results:
Good inter-rater concordance across readers was noted for both PET/CT (Finn's coefficient of reliability for overall scan certainty: 0.85,p < 0.01) and combined DxCT-PET/CT (0.59,p < 0.01). Overall certainty and concordance between PET/CT and combined DxCT-PET/CT datasets were similar (overall scan certainty: 92% ± 16 vs. 92% ± 17,p = 0.43), with no significant advantage for adding DxCT across different anatomic locations or clinical parameters. A slight predilection for combined DxCT-PET/CT was noted when interpreting images acquired for the initial staging of prostate cancer (89% ± 16 vs. 93% ± 17,p = 0.08).
Conclusion:
Good inter-reader concordance can be achieved across different training levels with PSMA-PET/CT. Furthermore, using DxCT concurrent with PSMA-PET/CT does not significantly improve diagnostic certainty for most indications but may be useful for initial staging.
More Related Videos
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
09:55Radiosynthesis, Quality Control, and Small Animal Positron Emission Tomography Imaging of 68Ga-Labelled Nano Molecules
Published on: October 4, 2024
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...