Related Experiment Video
Updated: Jun 19, 2026

The 4-vessel Sampling Approach to Integrative Studies of Human Placental Physiology In Vivo
Published on: August 2, 2017
External validation of and improvement upon a model for the prediction of placenta accreta spectrum severity using
Magdalena Kolak1, Stephen Gerry2, Hubert Huras1
1Department of Obstetrics and Perinatology, Medical College, Jagiellonian University, Krakow, Poland.
Introduction:
This study aimed to validate the Sargent risk stratification algorithm for the prediction of placenta accreta spectrum (PAS) severity using data collected from multiple centers and using the multicenter data to improve the model.
Material And Methods:
We conducted a multicenter analysis using data collected for the IS-PAS database. The Sargent model's effectiveness in distinguishing between abnormally adherent placenta (FIGO grade 1) and abnormally invasive placenta (FIGO grades 2 and 3) was evaluated. A new model was developed using multicenter data from the IS-PAS database.
Results:
The database included 315 cases of suspected PAS, of which 226 had fully documented standardized ultrasound signs. The final diagnosis was normal placentation in 5, abnormally adherent placenta/FIGO grade 1 in 43, and abnormally invasive placenta/FIGO grades 2 and 3 in 178. The external validation of the Sargent model revealed moderate predictive accuracy in a multicenter setting (C-index 0.68), compared to its higher accuracy in a single-center context (C-index 0.90). The newly developed model achieved a C-index of 0.74.
Conclusions:
The study underscores the difficulty in developing universally applicable PAS prediction models. While models like that of Sargent et al. show promise, their reproducibility varies across settings, likely due to the interpretation of the ultrasound signs. The findings support the need for updating the current ultrasound descriptors and for the development of any new predictive models to use data collected by different operators in multiple clinical settings.
More Related Videos
09:51Model Surgical Training: Skills Acquisition in Fetoscopic Laser Photocoagulation of Monochorionic Diamniotic Twin Placenta Using Realistic Simulators
Published on: March 21, 2018
06:43High Frequency Ultrasound for the Analysis of Fetal and Placental Development In Vivo
Published on: November 8, 2018
Related Concept Videos
Improving Translational Accuracy
Improving Translational Accuracy
Expected Frequencies in Goodness-of-Fit Tests
Testing a Claim about Standard Deviation
The hypothesis testing for the claim of population standard deviation (or variance) requires the data and samples to be random and unbiased. The population distribution also must be normal. There is no specific requirement on the sample size as the estimation is based on the chi-square distribution.
As a first step, the hypothesis (null and alternative) concerning the claim about...
Data Validation
Key parameters for method validation include:
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...