Related Experiment Video
Updated: Jun 15, 2025

The Rigid Tube as an Alternative in Controlling the Problematic Airway
Published on: June 6, 2020
Reverse tube direction and epistaxis in left nasotracheal intubation: a randomized controlled trial
Jun-Young Park1, Jihion Yu1, Chan-Sik Kim1
1Department of Anesthesiology and Pain Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea.
Background:
The incidence of epistaxis during nasotracheal intubation via the left nostril is more frequent than that during intubation via the right nostril. This study evaluated the effect of the reverse bevel and tip direction of the nasotracheal tube on the incidence of epistaxis during nasotracheal intubation via the left nostril.
Methods:
Patients undergoing right-sided maxillofacial surgery requiring left nasotracheal intubation were randomly allocated to the control (tracheal tube in the conventional direction) or reverse (a 180˚ reverse direction, with the tube bevel facing the nasal septum and the leading edge (i.e., the tip) of the bevel pointing away from the nasal septum) groups (n = 37 for both). The primary outcome was the incidence of epistaxis evaluated using videolaryngoscopy.
Results:
The incidence of epistaxis in the reverse group was significantly lower than that in the control group (9 [24.3%] vs. 20 [54.1%], P = 0.009; relative risk: 0.45, 95% CI [0.24, 0.85], absolute risk reduction: 29.8%, number needed to treat: 3). The severity of epistaxis was significantly lower in the reverse group (P = 0.002). The first attempt nasal passage (P = 0.027) was significantly higher in the reverse group. Postoperative nasal pain was lower (P < 0.001), and patient satisfaction was higher (P < 0.001) in the reverse group. Nasotracheal tube-related complications did not occur in either group.
Conclusions:
The reverse bevel and tip direction of the nasotracheal tube reduced the incidence and severity of epistaxis and increased patient satisfaction among patients undergoing left nasotracheal intubation.
Related Concept Videos
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Epistaxis
Etiology
Possible causes of this condition include high blood pressure, trauma, low humidity, upper respiratory tract infections, allergies, foreign bodies, nasal inhalation of corticosteroids or illicit drugs, excessive use of decongestant nasal sprays, facial or nasal surgery, anatomic malformation, tumors, or systemic...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Suctioning the Nasopharyngeal Airway
Equipment Required