A Pilot and Feasibility Study of Continuous Cardiac Output and Blood Pressure Monitoring during Intermittent
Sofia Spano1,2, Akinori Maeda3, Joey Lam4
1Department of Intensive Care, Austin Hospital, Heidelberg, Victoria, Australia, sofia.spano@icloud.com.
Introduction:
Hypotension is common during intermittent hemodialysis (IHD) and may be due to a decreased cardiac index (CI). However, no study has simultaneously and continuously measured CI and mean arterial pressure (MAP) to understand the prevalence, severity, and duration of CI decreases or relate them to MAP, blood volume (BV), and net ultrafiltration (NUF) rate.
Methods:
In a prospective, pilot and feasibility investigation, we studied 10 chronic IHD patients. We used the ClearSight System™ to continuously monitor CI and MAP; the CRIT-LINE®IV monitor to detect BV changes and collected data on NUF rate.
Results:
Device tolerance and compliance were 100%. All patients experienced at least ≥1 episode of severe CI decrease (>25% from baseline), with a median duration of 24 min (IQR 6-87) and of 68 min [14-106] for moderate decreases (>15% but ≤25% from baseline). Eight patients experienced a low CI state (<2.2 L/min/m2). The lowest CI was 0.9 L/min/m2 with a concomitant MAP of 94 mm Hg. When the fall in CI was severe, MAP increased in 58% of cases and remained stable in 28%. Overall, CI decreased by -0.55 L/min/m2 when BV decrease was moderate versus mild (p < 0.001) and by -0.8 L/min/m2 when NUF rate was high versus low (p < 0.001).
Conclusion:
Continuous CI monitoring is feasible in IHD and shows frequent moderate-severe CI decreases, sometimes to low CI state levels. Such decreases are typically associated with markers of decreased intravascular volume status but not with a decrease in MAP, implying marked vasoconstriction.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)