Using Extraordinary Optical Transmission to Quantify Cardiac Biomarkers in Human Serum
Published on: December 13, 2017
A rapid noninvasive wearable device for assessing cardiac troponin I level
William Franklin Peacock1, Karina Melissa Soto-Ruiz2, Allan S Jaffe3
1Department of Emergency Medicine, Baylor College of Medicine, Houston, TX, USA.
Objective:
Chest pain, a common emergency department presentation, requires rapid evaluation. The current gold standard of care is serial troponin measurements from blood draws along with an electrocardiogram and clinical presentation. However, an optical technology-based noninvasive wearable device, the Infrasensor, which can rapidly and transcutaneously assesses cardiac troponin I (cTnI), was recently developed. We aimed to perform a pilot study to evaluate the performance of the Infrasensor in cTnI defined cohorts.
Methods:
This was a 10-hospital prospective observational study in healthy US subjects with a normal cTnI level and in patients with an elevated local cTnI level. Healthy subjects as determined by a negative questionnaire and bloodwork underwent 3-minute Infrasensor measurement and levels of high-sensitivity cTnI (hs-cTnI), n-terminal pro-B-type natriuretic peptide (NTproBNP), creatinine, and glycosylated hemoglobin (HbA1c) were evaluated from blood. Patients with elevated cTnI had the same Infrasensor and blood sample measurements. Using a fivefold cross-validation technique, cTnI-based binary classification models that did and did not include age were trained on 80% and validated on 20% of the dataset (n=168; elevated hs-cTnI equally partitioned into five nearly equally-sized subsets ).
Results:
Of 840 patients, 727 (87.5%) had normal (nonelevated) cTnI levels while the remaining 113 had elevated cTnI. Median age was 61 years (interquartile range, 52-71 years) for the elevated cohort and 48 years (interquartile range, 32-57 years) for the nonelevated. Overall, 416 (50.5%) were female, with 33 of 113 (29.2%) in the elevated cohort and 383 of 727 (52.7%) in the nonelevated cohort. Overall, the sensitivity, specificity, negative and positive predictive values of the Infrasensor for identifying elevated cTnI were 0.90, 0.70, 0.98 and 0.48, respectively, with a C-statistic of 0.90 (95% confidence interval, 0.89-0.99).
Conclusion:
The Infrasensor accurately identifies elevated cTnI within 3 minutes of application.
More Related Videos
07:40Impact of High-intensity Interval Exercise and Moderate-Intensity Continuous Exercise on the Cardiac Troponin T Level at an Early Stage of Training
Published on: October 10, 2019
04:24A Novel Digital Platform for a Monitored Home-based Cardiac Rehabilitation Program
Published on: April 19, 2019
Related Concept Videos
Blood Studies for Cardiovascular System I: Cardiac Biomarkers
The essential diagnostic tools for detecting myocardial necrosis and monitoring individuals suspected of having acute coronary syndrome (ACS) include:
Troponins
Troponins, particularly cardiac troponins I and T, are the most precise and sensitive markers of myocardial injury. They are detectable within 4-6 hours of myocardial injury and remain...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Exercise Stress Test
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...