A Safety-Centric Study on the Use of Inflatable Abdominal Binders for Managing Orthostatic Hypotension
Milan Toma1, Rejath Jose1, Faiz Syed2
1Department of Osteopathic Manipulative Medicine, College of Osteopathic Medicine, New York Institute of Technology, Old Westbury, NY 11568, USA.
Abstract:
The study focuses on the design and evaluation of inflatable abdominal binders for managing Orthostatic Hypotension. Orthostatic hypotension is a condition characterized by a significant drop in blood pressure when a person stands up, leading to symptoms such as dizziness, lightheadedness, and even fainting. The management of orthostatic hypotension typically involves a combination of pharmacological and non-pharmacological strategies. In the context of this research, an inflatable abdominal binder was designed, leveraging components that are not only economically viable but also easily obtainable. The evaluation of this device was conducted using a medical education manikin, specifically the CAE iStan manikin. The results demonstrated a correlation between the inflation values of the belt and the resulting pressure values exerted on the body. The general recommendation for an abdominal binder is to exert a pressure of 20-40 mmHg. Contrary to this, the study found that to maintain safe external pressure on the abdomen, the binder should not be inflated over 25 mmHg. This safety threshold was used as a reference point in the study, suggesting a potential need to revisit the standard recommendations for abdominal binder pressure. Further research is needed to assess the device's effectiveness in human subjects and to potentially redefine the safe and effective pressure range for abdominal binders.
More Related Videos
14:52Computerized Dynamic Posturography for Postural Control Assessment in Patients with Intermittent Claudication
Published on: December 11, 2013
06:51Development of an Algorithm to Perform a Comprehensive Study of Autonomic Dysreflexia in Animals with High Spinal Cord Injury Using a Telemetry Device
Published on: July 29, 2016
Related Concept Videos
Pre-Procedural Guidelines for Assessing Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.