Related Experiment Video
Updated: Jun 11, 2025

Measurement of Dynamic Force Acted on Water Strider Leg Jumping Upward by the PVDF Film Sensor
Published on: August 3, 2018
Potential of Non-Contact Dynamic Response Measurements for Predicting Small Size or Hidden Damages in Highly Damped
Zakrya Azouz1, Barmak Honarvar Shakibaei Asli1, Muhammad Khan1
1Centre for Life-Cycle Engineering and Management, Faculty of Engineering and Applied Sciences, Cranfield University, Cranfield, Bedfordshire MK43 0AL, UK.
Abstract:
Vibration-based structural health monitoring (SHM) is essential for evaluating structural integrity. Traditional methods using contact vibration sensors like accelerometers have limitations in accessibility, coverage, and impact on structural dynamics. Recent digital advancements offer new solutions through high-speed camera-based measurements. This study explores how camera settings (speed and resolution) influence the accuracy of dynamic response measurements for detecting small cracks in damped cantilever beams. Different beam thicknesses affect damping, altering dynamic response parameters such as frequency and amplitude, which are crucial for damage quantification. Experiments were conducted on 3D-printed Acrylonitrile Butadiene Styrene (ABS) cantilever beams with varying crack depth ratios from 0% to 60% of the beam thickness. The study utilised the Canny edge detection technique and Fast Fourier Transform to analyse vibration behaviour captured by cameras at different settings. The results show an optimal set of camera resolutions and frame rates for accurately capturing dynamic responses. Empirical models based on four image resolutions were validated against experimental data, achieving over 98% accuracy for predicting the natural frequency and around 90% for resonance amplitude. The optimal frame rate for measuring natural frequency and amplitude was found to be 2.4 times the beam's natural frequency. The findings provide a method for damage assessment by establishing a relationship between crack depth, beam thickness, and damping ratio.
Related Concept Videos
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by...
Types of Damping
Non-destructive Tests for Concrete Strength
Impact Loading
In cases of elastic deformation,...
Damped Oscillations
Although friction and other non-conservative...
Residual Stresses in Bending