A new simple technique for stabilizing the guidewire position within the left ventricle during transcatheter mitral
Kothandam Sivakumar1, Pramod Sagar1, Puthiyedath Thejaswi1
1Department of Pediatric Cardiology, Institute of Cardio Vascular Diseases, Madras Medical Mission, Chennai, India.
Abstract:
Transcatheter mitral valve-in-valve implantation is a preferred treatment for degenerating mitral bioprosthetic valves in high-risk surgical patients. A balloon-expandable transcatheter heart valve delivered through a postero-inferior transseptal puncture is deployed within the prosthesis over a guidewire secured in the left ventricle. Patients with aneurysmal left atrium and altered angulation between the planes of atrial septum and mitral prosthesis have unstable position of the guidewire that flips out of the left ventricle into the left atrium when the valve delivery system is advanced. Instead of a transapical access to snare the guidewire and create a railroad in such instances, we report a new technique of transarterial retrograde snaring of the guidewire in the left ventricle for stabilization.