Related Experiment Video
Updated: Jun 11, 2025

A Practical Guide for the Production and PET/CT Imaging of 68Ga-DOTATATE for Neuroendocrine Tumors in Daily Clinical Practice
Published on: April 17, 2019
Deep-learning-based Attenuation Correction for 68Ga-DOTATATE Whole-body PET Imaging: A Dual-center Clinical Study
Mahsa Sobhi Lord1, Jalil Pirayesh Islamian1, Negisa Seyyedi2
1Tabriz University of Medical Sciences School of Medicine, Department of Medical Physics, Tabriz, Iran.
Objectives:
Attenuation correction is a critical phenomenon in quantitative positron emission tomography (PET) imaging with its own special challenges. However, computed tomography (CT) modality which is used for attenuation correction and anatomical localization increases patient radiation dose. This study was aimed to develop a deep learning model for attenuation correction of whole-body 68Ga-DOTATATE PET images.
Methods:
Non-attenuation-corrected and computed tomography-based attenuation-corrected (CTAC) whole-body 68Ga-DOTATATE PET images of 118 patients from two different imaging centers were used. We implemented a residual deep learning model using the NiftyNet framework. The model was trained four times and evaluated six times using the test data from the centers. The quality of the synthesized PET images was compared with the PET-CTAC images using different evaluation metrics, including the peak signal-to-noise ratio (PSNR), structural similarity index (SSIM), mean square error (MSE), and root mean square error (RMSE).
Results:
Quantitative analysis of four network training sessions and six evaluations revealed the highest and lowest PSNR values as (52.86±6.6) and (47.96±5.09), respectively. Similarly, the highest and lowest SSIM values were obtained (0.99±0.003) and (0.97±0.01), respectively. Additionally, the highest and lowest RMSE and MSE values fell within the ranges of (0.0117±0.003), (0.0015±0.000103), and (0.01072±0.002), (0.000121±5.07xe-5), respectively. The study found that using datasets from the same center resulted in the highest PSNR, while using datasets from different centers led to lower PSNR and SSIM values. In addition, scenarios involving datasets from both centers achieved the best SSIM and the lowest MSE and RMSE.
Conclusion:
Acceptable accuracy of attenuation correction on 68Ga-DOTATATE PET images using a deep learning model could potentially eliminate the need for additional X-ray imaging modalities, thereby imposing a high radiation dose on the patient.
More Related Videos
09:55Radiosynthesis, Quality Control, and Small Animal Positron Emission Tomography Imaging of 68Ga-Labelled Nano Molecules
Published on: October 4, 2024
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020