Related Experiment Video
Updated: May 1, 2026

06:23
Assessment of Plasma Coagulation on Liver Tissue in a Large Animal Model In Vivo
Published on: August 4, 2018
8.8K
Refining Liposuction Safety and Efficacy: Surgeon Learning-Curve Analysis With Helium-Based Plasma Integration.
Aesthetic Surgery Journal. Open Forum
|October 18, 2024
Summary
This study found that using a helium-based plasma device with liposuction improved patient outcomes and safety. Continued use by the principal investigator demonstrated a learning curve effect, with no serious adverse events reported.
Area of Science:
- Aesthetic Medicine
- Minimally Invasive Procedures
- Energy-Based Devices
Background:
- Critical evaluation of medical advancements is essential for improving patient outcomes and safety.
- Minimally invasive, energy-based devices are increasingly utilized in aesthetic medicine.
- Ongoing assessment of new technologies is crucial for clinical practice refinement.
Purpose of the Study:
- To evaluate retrospective data on liposuction procedures.
- To assess safety and outcomes with adjunct helium-based plasma device utilization.
- To compare three treatment groups and delineate the learning curve.
Main Methods:
- Retrospective chart review of 150 healthy patients (≥18 years).
- Three groups: ultrasonic-assisted liposuction, liposuction with helium-based plasma device, and recent liposuction with helium-based plasma device.
- Minimum 6-month postoperative follow-up for all patients.
Main Results:
- 150 patients enrolled, primarily treated on hips and abdomen.
- Significant relationship found between pain and treatment groups (P = .013).
- No serious or unexpected adverse events (AEs) occurred; all resolved by follow-up.
Conclusions:
- Continued use of the helium-based plasma device by the principal investigator correlates with improved patient outcomes and safety.
- The helium-based plasma device is safe for use in combination with liposuction procedures.
- Data support the efficacy and safety profile of adjunct helium-based plasma device in liposuction.
More Related Videos
Related Concept Videos
Ultrasound II: Endoscopic Ultrasound and FibroScan
1.3K
Endoscopic Ultrasound (EUS) and FibroScan are valuable diagnostic tools in gastroenterology and hepatology, each with specific applications and techniques.
Endoscopic Ultrasound (EUS):
Endoscopic Ultrasound (EUS):
1.3K
Pharmacokinetics in Obese Patients: Drug Absorption and Distribution
440
Obesity significantly alters the pharmacokinetic processes of drug absorption and distribution, presenting unique challenges in medical treatment. The increased fat tissue and decreased lean muscle in obese individuals can significantly affect how drugs are absorbed into the body and distributed across different tissues. This alteration can lead to variances in the effectiveness and safety of medications, necessitating adjustments in dosing or drug selection for obese patients.One notable...
440
Pharmacokinetics in Obese Patients: Drug Metabolism and Excretion
324
Drug metabolism, a critical process in the liver, involves two primary phases: Phase I reactions and Phase II conjugation. Obesity introduces significant alterations in this metabolic process, primarily due to fatty infiltration of the liver, leading to conditions such as nonalcoholic fatty liver disease (NAFLD). This condition can modify the activities of both Phase I and II enzymes, impacting how drugs are metabolized in obese patients.Phase I metabolism sees variable effects across...
324