Related Experiment Video
Updated: Jun 10, 2025

Author Spotlight: Workflow for Integrating POCUS Data into EHR for Managing Heart Failure Patients
Published on: July 12, 2024
Prognostic Role of Ultrasound Diagnostic Methods in Patients with Acute Decompensated Heart Failure
Zhanna D Kobalava1, Tolkacheva Veronika Vladimirovna1, Sarlykov Bekbolot Kanatbekovich2
1Department of Internal Diseases with Courses of Cardiology and Functional Diagnostics, Peoples' Friendship University of Russia, Moscow, Russia.
Objectives:
To evaluate the prognostic value (total mortality + repeated hospitalization for heart failure (HF)) of ultrasound diagnostic methods in patients with acute decompensated HF (ADHF).
Methods:
The subjects were patients with chronic HF, who were hospitalized for ADHF. Using ultrasound methods-lung ultrasound, ultrasound assessment of hepatic venous congestion as per the venous excess ultrasound (VExUS) protocol, and indirect elastometry-we assessed the number of B-lines, hepatic venous congestion, and liver density of the patients. Clinical outcomes were assessed using a structured telephone survey method at 1, 3, 6, and 12 months after discharge. Combined overall mortality and readmission rates associated with HF were assessed. Threshold values for different methods for detecting congestion were set as follows: the number of B-lines in ultrasound data > 5; liver density > 6.2 kPa.
Results:
The subjects were 207 patients (54.1% male; mean age = 70.7 ± 12.8 years). A total of 63 (30.4%) endpoints and 23 (11.1%) deaths were detected within 364 days (IQR = 197-365). Liver density > 6.2 kPa had a hazard ratio (HR) of 1.9 (95% CI: 1.0-3.3; p = 0.029). Hepatic venous congestion (VExUS protocol) had HR of 2.8 (95% CI: 1.3-5.7; p = 0.004). There was a significant increase in the risk of overall prognostic value in the presence of congestion, identified by liver fibroelastometry + lung ultrasound (HR = 10.5, 95% CI: 2.3-46.2; p = 0.002). The ultrasound assessment of hepatic venous congestion (VExUS + lung ultrasound protocol) yielded HR of 16.7 (95% CI: 3.9-70.7; p < 0.001). For all three methods combined, the overall HR was 40.1 (95% CI: 6.6-243.1; p < 0.001).
Conclusions:
A combination of ultrasound diagnostic methods that include the number of B-lines, presence of hepatic venous congestion according to the VExUS protocol, and liver density according to indirect elastometry at discharge may have an independent prognostic value for patients with ADHF.
Related Concept Videos
Acute Coronary Syndrome III: Diagnostic studies
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Dysrhythmias V: Evaluating Dysrhythmias
Rheumatic Heart Disease II: Clinical Manifestations and Diagnostic Studies

