Related Experiment Video
Updated: Jun 9, 2025

Ultrasound-based Pulse Wave Velocity Evaluation in Mice
Published on: February 14, 2017
Investigating the correlation of the second derivative of digital pulse wave (DPW) with QT variability index in women
Husain Ali Al-Byatee1, Amal Yousif Al-Yasiri2, Bassam Talib Al-Gailani1
1Department of Physiology, Mustansiriyah University.
Objective:
To determine the correlation between the second derivative of digital pulse wave and the QT variability index.
Methods:
The cross-sectional study was conducted from October 2021 to May 2022 at the Department of Physiology, College of Medicine, University of Mustansiriyah, Baghdad, Iraq, and comprised healthy women. Samples were raised by simple random technique. Digital pulse waves were captured using a fingertip pulse wave transducer. Lab Chart Pro version 7.2 was used to automatically detect and quantify the amplitude of A, B, C, D and E waves expressed by the second derivative. QT interval of each beat was recorded by electrocardiogram, and was calculated automatically via Lab chart Pro version 7.2 without averaging. Data was spread out on Microsoft Office Excel 2013 and analysed using SPSS version 26.
Results:
There were 55 women with mean age 37.4±9.9 years and mean body mass index 31.2±7.2kg/m2. Age was positively associated with QT variability index and normalised wave amplitude values of B/A and (B-C-D-E)/A (p<0.05).QT variability index was positively associated with the normalised values of the second derivative of digital pulse wave B/A and (B-C-D-E)/A (p<0.05).
Conclusions:
QT variability index I was significantly correlated with second derivative of photoplethysmogram, and both were affected by age and arterial stiffness.
More Related Videos
06:08Pulse Wave Velocity Testing in the Baltimore Longitudinal Study of Aging
Published on: February 7, 2014
11:04Quantification of Global Diastolic Function by Kinematic Modeling-based Analysis of Transmitral Flow via the Parametrized Diastolic Filling Formalism
Published on: September 1, 2014
Related Concept Videos
Special considerations while measuring pulse
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Rectangular and Triangular Pulse Function
For example, consider a rectangular pulse with a 5V amplitude, a 3-second duration, and centered at t=2 seconds. This pulse can be expressed using the rectangular function, written as,
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Quartile
1; 1; 2; 2; 4; 6; 6.8; 7.2; 8; 8.3; 9; 10; 10; 11.5
The median or second quartile is seven. The lower half of the...
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...