Pulse transit time as an index of vascular reactivity
Sheamaa Ahmed Abdullah1, Samar Imran Essa2, Bassam Talib Al-Gailani3
1Department of Physiology and Medical Physics, Mustansiriyah University, Baghdad, Iraq.
Abstract:
Pulse transit time (PTT) is a non-invasive method for measuring arterial compliance and stiffness, which are excellent predictors of cardiovascular disease. This study aims to determine whether PTT can be used to precisely monitor vascular reactivity in response to changes in hand posture and whether the digital pulse wave index of time-to-maximum slope (TMS) is a suitable alternative to PTT. Fifteen healthy, 22-year-old males participated in the study. The PTT was monitored from electrocardiogram (ECG) to digital pulse wave (DPW), and the morphological variable TMS of the DPW wave was estimated in beat-tobeat intervals for the individuals while their arms were raised and dropped. The results demonstrated that the PTT increased significantly with elevating the hand, and the correlation probability of the second polynomial fitness equation neared infinite. In addition, the PTT significantly correlated (P < 0.007) with the TMS of the DPW throughout the hand motions. The data indicate that PTT can represent local vascular responses during changes in hand position. In this study, we developed a new DPW index and suggest a TMS index as a viable substitute for PTT.
Related Concept Videos
Pulse
The pulse serves as a clinical...
Regulation of Pulse
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
Pulse Assessment Sites
Vascular Resistance
The primary determinants of vascular resistance are vessel diameter, blood viscosity, and vessel length. Among these, vessel diameter plays the most significant role due to the fourth power relationship described by...
Special considerations while measuring pulse