Axial compressive properties of round bamboo-fiber reinforced phosphogypsum composite short columns

Zhili Cui1, Zhenhua Jiao2, Wei Tong3

  • 1School of Mechanics and Photoelectric Physics, Anhui University of Science & Technology, Huainan, 232001, China. zhlcui@aust.edu.cn.

Scientific Reports
|October 22, 2024
PubMed

Related Concept Videos

Euler's Formula for Pin-Ended Columns01:21

Euler's Formula for Pin-Ended Columns

In structural engineering, the stability of columns under compressive axial loads is a critical consideration, described as buckling. A typical example involves a column PQ, which is pin-connected at both ends and subjected to a centric axial load F applied at one end, with a reaction force of F' = -F at the other end. Here, it is crucial to understand that when an applied load exceeds the critical load, buckling occurs as the system becomes unstable.
To calculate the critical load,...
292
Behavior of Concrete Under Compressive Load01:23

Behavior of Concrete Under Compressive Load

Concrete exhibits specific behaviors under different compressive loads. Understanding this is crucial for understanding its structural integrity. When concrete undergoes uniaxial compression, it tends to develop cracks that run parallel to the direction of the force. These parallel cracks stem from localized tensile stresses that occur perpendicular to the compression direction. Additionally, angled cracks may appear due to the formation of shear planes.
As the concrete specimen fractures under...
149
Strength of Cement01:20

Strength of Cement

Strength tests for cement are not performed directly on neat cement paste due to difficulty in obtaining consistent, reliable specimens. Instead, cement is typically tested in the form of cement-sand mortar.
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
126
Design of Columns under a Centric Load01:17

Design of Columns under a Centric Load

The design of columns under centric load is a fundamental aspect of structural engineering and is critical for ensuring the stability and integrity of structures. Euler's and Secant's formulas are central to understanding and calculating the critical load and deformation behaviors of columns, providing a basis for safe and effective structural design.
Euler's formula is applicable under the assumption that the column is a perfect, straight, homogenous prism, and it is operating...
104
Fiber Reinforced Concrete01:22

Fiber Reinforced Concrete

Fiber-reinforced concrete significantly enhances the structural and nonstructural properties of traditional concrete by incorporating fibers like steel, glass, and polymers. These fibers, varying from natural ones such as sisal and cellulose to manufactured ones like polypropylene and Kevlar, are mixed into hydraulic cement with aggregates. Steel fibers, often preferred for their robustness, contribute to improved ductility, toughness, and post-cracking performance. The concrete is classified...
71
Prismatic Beams: Problem Solving01:15

Prismatic Beams: Problem Solving

In the design of a supported timber beam subjected to a distributed load, both the beam's physical dimensions and the timber's characteristics, such as its grade and species, are critical. These factors determine the allowable stress values, which are crucial for calculating the necessary beam depth to ensure structural integrity and safety.
The design begins with analyzing the beam as a free body to identify moments and force balances, thereby determining support reactions. Next, the...
105