Abstract:
Cargo terminals, as pivotal hubs of mechanical activities, maritime shipping, and land transportation, are significant sources of air pollutants, exhibiting considerable spatiotemporal heterogeneity due to the complex and irregular nature of emissions. This study employed a high-density air sensor network with 17 sites across four functional zones in two Shanghai cargo terminals to monitor NO and NO2 concentrations with high spatiotemporal resolution post sensor data validation against regulatory monitoring stations. Notably, NO and NO2 concentrations within the terminal surged during the night, peaking at 06:00 h, likely due to local regulations on heavy-duty diesel trucks. Spatial analysis revealed the highest NO concentrations in the core operational areas and adjacent roads, with significantly lower levels in the outer ring, indicating strong emission sources and limited dispersion. Employing the lowest percentile method for baseline extraction from high-resolution data, this study identified local emissions as the primary source of NO, constituting over 80% of total emissions. Elevated background concentrations of NO2 suggested a gradual oxidation of NO into NO2, with local emissions contributing to 32-70% of the total NO2 concentration. These findings provide valuable insights into the NO and NO2 emission characteristics across different terminal areas, aiding decision-makers in developing targeted emission control policies.
More Related Videos
15:13High-resolution Spatiotemporal Analysis of Receptor Dynamics by Single-molecule Fluorescence Microscopy
Published on: July 25, 2014
10:29Calibrated Passive Sampling - Multi-plot Field Measurements of NH3 Emissions with a Combination of Dynamic Tube Method and Passive Samplers
Published on: March 21, 2016
Related Concept Videos
Atomic Emission Spectroscopy: Overview
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
Atomic Emission Spectroscopy: Lab
Atomic Emission Spectroscopy: Instrumentation