Exploration of the Conditions for Occurrence of Photoplethysmographic Signal Inversion above the Dorsalis Pedis
Fredrik Wilsbeck Jerve1, Dag Roar Hjelme1, Håvard Kalvøy2
1Department of Electronic Systems, Norwegian University of Science and Technology, 7034 Trondheim, Norway.
Abstract:
Inversion of the photoplethysmographic (PPG) signal is a rarely reported case. This signal anomaly can have implications for PPG-based cardiovascular assessments. The conditions for PPG signal inversion in the vicinity of the dorsalis pedis (DPA) artery of the foot were investigated. Wireless multi-wavelength PPG sensing with skin-probe contact pressure and local skin temperature were studied at different sensor positions, and the occurrence of inversion (OOI) was investigated. Twelve healthy adult volunteers were studied over four LED wavelengths at three levels of contact pressure for 11 probe positions. A novel algorithm quantified the proportion of inverted samples with respect to the abovementioned variables. Our algorithm classifying inverted vs. non-inverted pulses achieved 98.3% accuracy. Ten of the participants had at least one inverted signal identified. The impact of interindividual variation on inversion prevalence was large, but different LEDs, relative position to the DPA and sensor contact pressure also affected OOI. Skin surface and room temperatures showed no impact on OOI. Lateral measurements showed 39.6% more inversion at maximum compared to minimum contact pressure. Mechanical capillary bed variations and arterial reflections during venous engorgement are considered viable explanations for our observations. These findings motivate an expanded study of the occurrence of PPG signal inversion.
More Related Videos
Related Concept Videos
Pulse Assessment Sites
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessing Blood pressure in the Leg
Preparation: