Related Experiment Video
Updated: Jun 9, 2025

Contrast-Enhanced Subharmonic Aided Pressure Estimation SHAPE Using Ultrasound Imaging with a Focus on Identifying Portal Hypertension
Published on: December 5, 2020
Novel subharmonic-aided pressure estimation for identifying high-risk esophagogastric varices
Hidekatsu Kuroda1, Tamami Abe2, Naohisa Kamiyama3
1Division of Gastroenterology and Hepatology, Department of Internal Medicine, Iwate Medical University, Iwate Medical University School of Medicine, Nishitokuta 2-1-1, Yahaba-Cho, Shiwa-Gun, Yahaba, Iwate, 028-3694, Japan. hikuro@iwate-med.ac.jp.
Background:
Subharmonic-aided pressure estimation (SHAPE) is a technique for determining changes in ambient pressure. We aimed to analyze a novel SHAPE integrated into ultrasound diagnostic equipment to predict patients with liver cirrhosis at high risk of esophagogastric varices (EV).
Methods:
This prospective study included 111 patients with liver cirrhosis diagnosed between 2020 and 2023. We obtained liver stiffness measurements (LSM) and spleen stiffness measurements (SSM) using shear wave elastography and hepatic vein-portal vein (HV-PV) gradient using the SHAPE method. The EV risk was determined either as null, low, or high by esophagoscopy and Child-Pugh stage.
Results:
HV-PV gradient increased concordantly with the increase in EV risk (- 7.0 dB in null-risk, - 4.4 dB in low-risk, and - 2.0 dB in high-risk) with statistically significant difference among any two groups. The most appropriate cut-off value of the HV-PV gradient was - 3.5 dB, and sensitivity, specificity, and positive and negative predictive values were 80.0%, 89.0%, 80.0%, and 88.0%, respectively. The areas under the curve values for predicting the high-risk EV were 0.920, 0.843, and 0.824 for the HV-PV gradient, LSM, and SSM, respectively.
Conclusions:
The novel SHAPE system demonstrated high accuracy in identifying patients with liver cirrhosis at a high risk of EV.
Related Concept Videos
Esophageal Varices-II: Clinical Features and Management
In the initial assessment, a thorough review of the patient's medical history is vital to identify risk factors such as liver disease, alcohol...
Esophageal Varices-I: Introduction
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):