Related Experiment Video
Updated: Jun 8, 2025

A Basic Positron Emission Tomography System Constructed to Locate a Radioactive Source in a Bi-dimensional Space
Published on: February 1, 2016
Segmented readout for Cherenkov time-of-flight positron emission tomography detectors based on bismuth germanate
Minseok Yi1,2,3, Daehee Lee1, Alberto Gola4
1Department of Biomedical Engineering, University of California, Davis, USA.
Abstract:
Positron emission tomography (PET) is the most sensitive biomedical imaging modality for non-invasively detecting and visualizing positron-emitting radiopharmaceuticals within a subject. In PET, measuring the time-of-flight (TOF) information for each pair of 511-keV annihilation photons improves effective sensitivity but requires high timing resolution. Hybrid materials that emit both scintillation and Cherenkov photons, such as bismuth germanate (BGO), recently offer the potential for more precise timing information from Cherenkov photons while maintaining adequate energy resolution from scintillation photons. However, a significant challenge in using such hybrid materials for TOF PET applications lies in the event-dependent timing spread caused by the mixed detection of Cherenkov and scintillation photons due to relatively lower production of Cherenkov photons. This study introduces an innovative approach by segmenting silicon photomultiplier (SiPM) pixels coupled to a single crystal, rather than using traditional SiPMs that are as large as or larger than the crystals they read. We demonstrated that multiple time stamps and photon counts obtained from the segmented SiPM can classify events by providing temporal photon density, effectively addressing this challenge. The approach and findings would lead to new opportunities in applications that require precise timing and photon counting, spanning the fields of medical imaging, high-energy physics, and optical physics.
More Related Videos
06:28Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera
Published on: January 30, 2020
10:24Neutron Radiography and Computed Tomography of Biological Systems at the Oak Ridge National Laboratory's High Flux Isotope Reactor
Published on: May 7, 2021
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...