Related Experiment Video
Updated: Jun 13, 2026

05:25
Knotless Independent Double-Row Repair and Biceps Augmentation for Anterosuperior Rotator Cuff Tears
Published on: January 23, 2026
Clinical and Radiologic Outcomes of Bioinductive Collagen Implant Augmentation in Sugaya Type III Rotator Cuff
Daehee Lee1, Jaewook Park1, Jaesung Yoo1,2
1Department of Orthopaedic Surgery, WELIVE Hoispital, Asan 31465, Republic of Korea.
Diagnostics (Basel, Switzerland)
|June 12, 2026
Summary
This study found that bioinductive collagen implants improved pain and function in patients with Sugaya type III rotator cuff re-tears. Tendon thickness also increased, but further research is needed due to the small sample size.
Area of Science:
- Orthopedic Surgery
- Regenerative Medicine
- Sports Medicine
Background:
- Sugaya type III rotator cuff re-tears involve preserved tendon continuity but reduced thickness, leading to pain and dysfunction.
- Bioinductive collagen implants offer potential for enhanced tendon healing, yet clinical data in this specific patient group is limited.
- Evaluating the efficacy of bioinductive collagen implants in augmenting arthroscopic repair for Sugaya type III re-tears is crucial.
Purpose of the Study:
- To assess the clinical and radiological outcomes of arthroscopic rotator cuff repair augmented with a bioinductive collagen implant.
- To investigate the impact of this augmentation on pain, function, and tendon morphology in patients with Sugaya type III re-tears.
Main Methods:
- A retrospective case series of 15 patients with MRI-confirmed Sugaya type III re-tears.
- Clinical outcomes (VAS, ASES, SANE, WORC scores) were evaluated preoperatively and at 6 and 12 months postoperatively.
- MRI was used to measure supraspinatus tendon thickness, with non-parametric statistical analysis applied.
Main Results:
- Significant improvements were observed in pain scores (VAS) and functional scores (ASES, SANE, WORC) at 12 months post-surgery.
- Supraspinatus tendon thickness increased significantly from 4.8 mm to 6.9 mm at 12 months (adjusted p < 0.001).
- No instances of graft failure were detected on follow-up MRI.
Conclusions:
- Arthroscopic repair combined with bioinductive collagen implant augmentation shows promise for short-term improvements in pain, function, and tendon thickness in Sugaya type III re-tears.
- The study's small sample size and retrospective design necessitate cautious interpretation of findings.
- Further prospective comparative studies are recommended to validate these results and establish the long-term efficacy of this treatment approach.
