With buildings representing a substantial portion of global energy consumption, exploring alternatives to traditional fossil fuel-based heating and cooling systems is critical. Thermoelectricity offers a promising solution by converting temperature differentials into electrical voltage or vice versa, enabling efficient indoor thermal regulation. This paper presents a comprehensive investigation into the integration of thermoelectric wall systems for sustainable building climate control through numerical simulations and experimental analyses. Numerical simulations using computational fluid dynamics (CFD) techniques were conducted to model fluid flow and heat transfer within the thermoelectric wall systems under various operating conditions. These simulations provided insights into the system's thermal behavior, which were validated through experimental setups designed to measure temperature differentials, airflow rates, and power consumption. The results showed that power consumption is directly correlated with electrical current, ranging from 0.19 W to 77.4 W as the current increased from 0.1 A to 2 A. Additionally, the heat absorbed by the system increased significantly with electrical current, by 706-1044%, depending on the air velocity. The thermal energy released from the hot side of the thermoelectric modules also rose substantially, ranging from 9850 to 5285% with increasing electrical current, and from 275 to 51% with higher air velocities. Moreover, increasing air velocity led to a 6.78-9.37% reduction in power consumption for currents between 0.1 A and 2 A. The coefficient of performance (COP) analysis revealed that optimizing both electrical current and air velocity is essential for maximizing system efficiency. While fan power consumption reduces COP at higher air velocities, neglecting fan power consumption results in COP improvements ranging from 6.5 × 10⁻⁴ to 49.0%. These findings highlight the potential of thermoelectric wall systems to enhance indoor comfort and energy efficiency in buildings.
More Related Videos
Related Concept Videos
Thermal Insulation in Masonry Walls
External insulation can be applied using an Exterior Insulation and Finish System (EIFS), which involves affixing panels of plastic foam to the wall and covering them with a polymeric stucco reinforced with glass fiber mesh....
Conduction, Convection and Radiation: Problem Solving
In order to solve a problem related to heat transfer, first of all, the situation needs to be examined to determine the type of heat transfer involved. This could...
Thermodynamic Systems
Consider an example of tea boiling in a kettle. The...
Mechanism of heat transfer
Design Example: Sustainability in Concrete Building
There are multiple approaches to achieve sustainability in a commercial concrete building. For instance, construct a concrete parking area under the building, utilizing pervious concrete paver blocks in open areas to facilitate rainwater collection through an underground...
Refrigerators and Heat Pumps