Related Experiment Video
Updated: Jun 8, 2025

Augmenting Large Language Models via Vector Embeddings to Improve Domain-Specific Responsiveness
Published on: December 6, 2024
Comparative Accuracy of ChatGPT 4.0 and Google Gemini in Answering Pediatric Radiology Text-Based Questions
Mohammed Abdul Sami1, Mohammed Abdul Samad2, Keyur Parekh1
1Department of Diagnostic Radiology and Nuclear Medicine, Rush University Medical Center, Chicago, USA.
Aims And Objectives:
This study evaluates the accuracy of two AI language models, ChatGPT 4.0 and Google Gemini (as of August 2024), in answering a set of 79 text-based pediatric radiology questions from "Pediatric Imaging: A Core Review." Accurate interpretation of text and images is critical in radiology, making AI tools valuable in medical education.
Methods:
The study involved 79 questions selected from a pediatric radiology question set, focusing solely on text-based questions. ChatGPT 4.0 and Google Gemini answered these questions, and their responses were evaluated using a binary scoring system. Statistical analyses, including chi-square tests and relative risk (RR) calculations, were performed to compare the overall and subsection accuracy of the models.
Results:
ChatGPT 4.0 demonstrated superior accuracy, correctly answering 83.5% (66/79) of the questions, compared to Google Gemini's 68.4% (54/79), with a statistically significant difference (p=0.0255, RR=1.221). No statistically significant differences were found between the models within individual subsections, with p-values ranging from 0.136 to 1.
Conclusion:
ChatGPT 4.0 outperformed Google Gemini in overall accuracy for text-based pediatric radiology questions, highlighting its potential utility in medical education. However, the lack of significant differences within subsections and the exclusion of image-based questions underscore the need for further research with larger sample sizes and multimodal inputs to fully assess AI models' capabilities in radiology.
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET