Selecting optimal wearables for measuring physiological arousal in robot-delivered mindfulness-based exercises
Stefania V Vacaru1,2, Lok-Pui Lau1, Kyra Frederiks1
1Department of Clinical Child and Family Studies & Amsterdam Public Health, Vrije Universiteit Amsterdam, Amsterdam, Netherlands.
Summary
This study compared two devices for measuring electrodermal activity (EDA) during robot-led relaxation. The Shimmer device showed higher sensitivity to stress and relaxation changes than the Empatica E4.
Area of Science:
- Robotics
- Psychophysiology
- Human-Computer Interaction
Background:
- Social robots offer therapeutic potential, but accurate affective outcome assessment is crucial.
- Selecting appropriate devices for recording autonomic responses during interventions is essential for data quality and participant comfort.
Purpose of the Study:
- To compare the sensitivity and social validity of two electrodermal activity (EDA) devices: Shimmer and Empatica E4.
- To select the most suitable device for a larger study involving robot-delivered mindfulness-based relaxation exercises.
Main Methods:
- Assessed EDA sensitivity to stress-inducing and relaxation exercises using a Shimmer device (sock) and an Empatica E4 (wrist-worn).
- Evaluated device comfort and agreement using Bland-Altman analysis in 28 healthy adult volunteers.
- Corroborated physiological data with self-report measures.
Main Results:
- Both devices detected EDA variations corresponding to stress (increase) and relaxation (decrease) induced by robot-delivered exercises.
- The Shimmer device demonstrated higher sensitivity to EDA changes compared to the Empatica E4.
- No significant differences in wearing comfort were found between the devices, but Bland-Altman analysis indicated low agreement.
Conclusions:
- While both devices show promise for measuring psychophysiological responses in robot-assisted interventions, the Shimmer device appears more sensitive.
- Device selection should consider the specific demands of the intervention and the need for accurate EDA measurement.
- Further research can refine the use of wearable sensors in therapeutic social robot applications.
Related Concept Videos
Equipments Used to Measure Body Temperature
2.1K
Body temperature can be assessed using various devices and measured in Celsius or Fahrenheit.
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
2.1K
Equipments Used To Measure Blood Pressure
3.4K
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
3.4K