Related Experiment Video
Updated: May 7, 2026

Multimodal Volumetric Retinal Imaging by Oblique Scanning Laser Ophthalmoscopy oSLO and Optical Coherence Tomography OCT
Published on: August 4, 2018
Widefield optical coherence tomography by electro-optical modulation
Dorian R Urban1,2,3, Pavel Novak1, Miguel A Preciado1
1Optos PLC, Queensferry House, Enterprise Way, Dunfermline KY11 8GR, Scotland, UK.
Abstract:
Optical coherence tomography (OCT) is a unique imaging modality capable of axial sectioning with a resolution of only a few microns. Its ability to image with high resolution deep within tissue makes it ideal for material inspection, dentistry, and, in particular, ophthalmology. Widefield retinal imaging has garnered increasing clinical interest for the detection of numerous retinal diseases. However, real-time applications in clinical practice demand the contrast of swept-source OCT at scan speeds that limit their depth range. The curvature of typical samples, such as teeth, corneas, or retinas, thus restricts the field-of-view of fast OCT systems. Novel high-speed swept sources are expected to further improve the scan rate; however, not without exacerbating the already severe trade-off in depth range. Here, we show how, without the need for mechanical repositioning, harmonic images can be rapidly synthesized at any depth. This is achieved by opto-electronic modulation of a single-frequency swept source laser in tandem with tailored numerical dispersion compensation. We demonstrate experimentally how real-time imaging of highly-curved samples is enabled by extending the effective depth-range 8-fold. Even at the scan speed of a 400 kHz swept source, harmonic OCT enables widefield retinal imaging.
More Related Videos
Related Concept Videos
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Confocal Fluorescence Microscopy
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...

