Universal carbon nanotubes-polybenzimidazole SPME coating and its application for both gas and liquid chromatography
Igor Gustavo Carvalho Oliveira1,2, Khaled Murtada1, Maria Eugênia Costa Queiroz2
1Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, ON, N2L 3G1, Canada. janusz@uwaterloo.ca.
Abstract:
In this study, we present a novel combination of carbon nanotubes (CNT), widely used as a sorbent material in solid-phase extraction-based methodologies, with polybenzimidazole (PBI), recently introduced as a universal binder for physical immobilization of sorbent particles. This combination was used to prepare CNT-PBI coated solid-phase microextraction (SPME) devices (fibers, arrows, and blades) suitable for both thermal and solvent desorption. The resulting CNT-PBI SPME devices presented excellent mechanical resistance and high thermal stability, capable of enduring multiple thermal desorption cycles without compromising extraction efficiency. They also demonstrated stability in a range of organic solvents commonly used for solvent desorption, with no swelling or shrinkage observed. We evaluated the performance of the CNT-PBI fibers in gas chromatography-mass spectrometry (GC-MS) analysis of BTEX (benzene, toluene, ethylbenzene and xylene) compounds, comparing them to carboxen/polydimethylsiloxane (CAR-PDMS) and CAR-PBI fibers. The CNT-PBI fibers showed superior extraction efficiency for benzene, toluene, and xylene. In liquid chromatography-mass spectrometry (LC-MS) analysis of drugs of abuse, CNT-PBI blades outperformed CNT blades prepared with a conventional polyacrylonitrile (PAN) binder in extracting non-polar drugs (log P > 2.8). Moreover, CNT-PBI blades demonstrated similar extraction performance to C18-PBI blades, considering the differences in particle-to-binder ratio and the coating thickness of each material. Comparing the extraction performance between CNT-PBI and CNT-PAN blades for liquid chromatography-high resolution mass spectrometry (LC-HRMS) untargeted analysis in water samples revealed that the binders (PBI and PAN) significantly influenced the sorption capabilities of the coating particles. These findings highlight the potential of solvent and thermally stable CNT-PBI devices for SPME in both GC and LC analyses.
More Related Videos
07:54Capillary Electrophoresis Mass Spectrometry Approaches for Characterization of the Protein and Metabolite Corona Acquired by Nanomaterials
Published on: October 27, 2020
09:12Functionalization of Single-walled Carbon Nanotubes with Thermo-reversible Block Copolymers and Characterization by Small-angle Neutron Scattering
Published on: June 1, 2016
Related Concept Videos
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...