Related Experiment Video
Updated: Jun 6, 2025

Hybrid µCT-FMT imaging and image analysis
Published on: June 4, 2015
Toward Foundation Models in Radiology? Quantitative Assessment of GPT-4V's Multimodal and Multianatomic Region
Quirin D Strotzer1, Felix Nieberle1, Laura S Kupke1
1From the Institute of Radiology (Q.D.S., L.S.K., G.N., A.K.M., S.M., I.E., J.R., C.W., C.S., O.W.H., A.S.) and Department of Cranio- and Maxillofacial Surgery (F.N.), University of Regensburg Medical Center, Franz-Josef-Strauss-Allee 11, 93053 Regensburg, Germany; Department of Radiology, Division of Neuroradiology, Massachusetts General Hospital, Harvard Medical School, Boston, Mass (Q.D.S.); Department of Radiology, Bayreuth Medical Center, Bayreuth, Germany (M.S.); Center of Neuroradiology, medbo District Hospital and University Medical Center Regensburg, Regensburg, Germany (I.W., C.W.); and Department of Radiology, Donaustauf Hospital, Donaustauf, Germany (O.W.H.).
Abstract:
Background Large language models have already demonstrated potential in medical text processing. GPT-4V, a large vision-language model from OpenAI, has shown potential for medical imaging, yet a quantitative analysis is lacking. Purpose To quantitatively assess the performance of GPT-4V in interpreting radiologic images using unseen data. Materials and Methods This retrospective study included single representative abnormal and healthy control images from neuroradiology, cardiothoracic radiology, and musculoskeletal radiology (CT, MRI, radiography) to generate reports using GPT-4V via the application programming interface from February to March 2024. The factual correctness of free-text reports and the performance in detecting abnormalities in binary classification tasks were assessed using accuracy, sensitivity, and specificity. The binary classification performance was compared with that of a first-year nonradiologist in training and four board-certified radiologists. Results A total of 515 images in 470 patients (median age, 61 years [IQR, 44-71 years]; 267 male) were included, of which 345 images were abnormal. GPT-4V correctly identified the imaging modality and anatomic region in 100% (515 of 515) and 99.2% (511 of 515) of images, respectively. Diagnostic accuracy in free-text reports was between 0% (0 of 33 images) for pneumothorax (CT and radiography) and 90% (45 of 50 images) for brain tumor (MRI). In binary classification tasks, GPT-4V showed sensitivities between 56% (14 of 25 images) for ischemic stroke and 100% (25 of 25 images) for brain hemorrhage and specificities between 8% (two of 25 images) for brain hemorrhage and 52% (13 of 25 images) for pneumothorax, compared with a pooled sensitivity of 97.2% (1103 of 1135 images) and pooled specificity of 97.2% (1084 of 1115 images) for the human readers across all tasks. The model exhibited a clear tendency to overdiagnose abnormalities, with 86.5% (147 of 170 images) and 67.7% (151 of 223 images) false-positive rates for the free-text and binary classification tasks, respectively. Conclusion GPT-4V, in its earliest version, recognized medical image content and reliably determined the modality and anatomic region from single images. However, GPT-4V failed to detect, classify, or rule out abnormalities in image interpretation. © RSNA, 2024 Supplemental material is available for this article.
More Related Videos
07:13Author Spotlight: An Efficient and Robust Software for Automated Fusion of Multiple Preclinical Imaging Modalities
Published on: October 27, 2023
09:55Radiosynthesis, Quality Control, and Small Animal Positron Emission Tomography Imaging of 68Ga-Labelled Nano Molecules
Published on: October 4, 2024
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...