Calibration of MAJIS (Moons And Jupiter Imaging Spectrometer). I. On-ground setup description and characterization

Mathieu Vincendon1, Pierre Guiot1, Benoît Lecomte1

  • 1Institut d'Astrophysique Spatiale, Université Paris-Saclay, CNRS, Bâtiment 121, 91400 Orsay, France.

PubMed
Summary

The Moon And Jupiter Imaging Spectrometer (MAJIS) was calibrated before its JUICE mission to Jupiter. This calibration ensured accurate measurements of Jupiter

Related Concept Videos

Instrument Calibration01:12

Instrument Calibration

Instrument calibration is essential for ensuring that instruments produce accurate and consistent results. It is vital in manufacturing, healthcare, testing laboratories, and scientific research. Calibration processes are specific to each instrument and help enhance data accuracy. Each instrument has a unique calibration process tailored to its design and function to improve data accuracy.
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
152
Common Leveling Mistakes and Errors01:17

Common Leveling Mistakes and Errors

A survey team is tasked with determining the elevation difference between points Point A and Point B, separated by uneven terrain. They use a leveling instrument and a leveling rod.Common MistakesMisreading the Rod: During a backsight reading at Point A, the instrumentman observes the rod partially obscured by tall grass. Instead of reading 1.135 m, they mistakenly record 1.735 m due to the misalignment of the crosshair with the wrong graduation. This error adds 0.600 m to all subsequent...
60
Conversion of Units01:36

Conversion of Units

Sometimes, there is a need to convert from one unit to another one. For instance, reading a cookbook in which quantities are expressed in units of liters or ounces may require conversion of quantities to cups. Or, when looking up directions on how to get to a location, we may be interested to know how many miles we are going to walk. In this case, we would have to convert units of feet or meters to miles.
The first step in the unit conversion is to list the given units and the units required...
22.1K
Mass Analyzers: Overview01:13

Mass Analyzers: Overview

The mass analyzer is a crucial component of the mass spectrometer. In the ionization chamber, the vaporized sample is bombarded with a high-energy electron beam to generate a radical cation and further fragment into neutral molecules, radicals, and cations. A series of negatively charged accelerator plates accelerate the cations into the mass analyzer. The mass analyzer separates ions according to their mass-to-charge (m/z) ratios and then directs them to the detector. The common types of mass...
587
Introduction and Methods of Leveling01:26

Introduction and Methods of Leveling

Leveling is a surveying procedure used to determine elevation differences between distant points. Elevation refers to the vertical distance above or below a reference datum, typically mean sea level (MSL). In the United States, elevations are often referenced to the mean sea level station at Father Point Rimouski along the St. Lawrence Seaway. To make the datum accessible, permanent markers are established throughout the region. These markers, called benchmarks, have known elevations. If the...
64
Design Example: Identifying the Locations of Monuments in the Field Using Global Positioning System Device01:30

Design Example: Identifying the Locations of Monuments in the Field Using Global Positioning System Device

Surveyors use Global Positioning System (GPS) technology to measure the precise location and elevation of points on Earth. In a recent survey, GPS receivers were used to determine the coordinates and elevations of two park monuments. The process involved careful mission planning, data collection, and correction to ensure accuracy. The survey began with mission planning to identify optimal satellite visibility and minimize Position Dilution of Precision (PDOP). A geodetic control point...
22