Related Experiment Video
Updated: Jun 4, 2025

Advanced Self-Healing Asphalt Reinforced by Graphene Structures: An Atomistic Insight
Published on: May 31, 2022
The Effect of Recycled Geogrid Fibres on Asphalt Concrete Performance: A Case Study from Poland
Grzegorz Mazurek1, Przemysław Buczyński1, Artur Kowalczyk1
1Department of Civil Engineering and Architecture, Kielce University of Technology, Al. Tysiąclecia Państwa Polskiego 7, 25-314 Kielce, Poland.
Abstract:
This study articulates findings from research pertaining to the utilisation of recycled geogrid in asphalt concrete. The issue of contamination of reclaimed waste with geosynthetic materials persists as a significant concern that warrants attention. In Poland, the allowable quantity of geogrid contaminants within the mineral-asphalt composition is 0.1% w/w. The preliminary evaluation of the validity of the research topic was conducted based on an analysis of correspondence and survey outcomes. The fundamental material research was executed employing elements of experimental design theory. The experimental domain considered two qualitative factors: the type of bituminous mixture for the binding layer (AC16W and AC22W) and the type of geogrid material (glass, carbon), in addition to two quantitative factors: the length of the recycled geogrid fibres ranging from 1 cm to 5 cm, and the quantity of recycled geogrid fibres varying from 0.2% to 1%. A generalised linear model was employed for the analysis, enabling the consideration of dependent qualitative factors in forecasting characteristics. The qualitative evaluation of the resultant solution was conducted using multi-criteria optimisation via the Harrington function. Consequently, recycled carbon mesh fibres demonstrated a notably positive impact, enhancing the material's quality by 22%. Regarding glass mesh, the fibre content should not exceed 0.2% in the AC22W mixture, whereas it can be increased to 1% in the AC16W mixture. Comparing all evaluated mixtures, it was ascertained that surpassing the allowable contamination limit of 0.1% in geogrid form does not result in a significant reduction in the quality of asphalt concrete compared to the reference mix.
Related Concept Videos
Fiber Reinforced Concrete
Abrasion Resistance of Concrete
One such test is the revolving disc test, where three plates...
Additives and Fillers in Concrete
The...
Effects of Air-entrainment in Concrete
Frost Resistant Concrete
Introducing microscopic air bubbles into the concrete mix through air entrainment creates small voids that accommodate ice expansion, thereby reducing internal pressures and preventing cracking. The optimal amount of...
Superplasticizers